Several years ago while making inductors for tuning a class E amplifier we
end up with a 4-1/2 turn inductor. The inductor used a 3F3 potcore, gapped I think, but it has been awhile. The inductor was driven hard but below saturation. The problem; the 1/2 turn got HOT. Four turns or five turns were ok. My physicist friend had an EE verify the problem 2000 miles away. So, can anyone tell me why 1/2 turn would make such a difference in the heating? Thanks, MikeK |