On Jun 1, 2:54*pm, Tim Shoppa wrote:
On May 29, 2:15*pm, JIMMIE wrote: On May 29, 10:59*am, wrote: On May 29, 8:23*am, JIMMIE wrote: I want to replace the vr 0A3 tube used in the bias circuit of a 6146B amp with a 75V zener string. Can I just directly replace the tube with the diodes or *will I need to make other modifications to the circuit? Jimmie Typical OA3 is idling with between 5 and 40mA of current flowing through it, so make sure the zener string can dissipate the power. (75V * 0.040A = 3 watts worst case, but I'd expect less idle current in a grid bias regulator.). If this is a major redesign you might want to use a solid state series pass regulator (e.g. TL783 or the like) and probably get rid of that old wirewound pot in the bias circuit. 0A3's are not unobtanium, rare, or expensive. I kinda like seeing VR tubes around the PA, nice purple/pink glow dims and brightens as I key, and if they're not glowing then something's wrong. It draws about 30ma calculated by measuring the voltage drop across the series dropping resistor. Once in a while it arcs, I think. I tried another tube and that seemed to fix it for a while but it started up again. There is a posssibility this is not the problem but for now it seems most likely. If I can easily replace it with a zener string I could be more sure that it is or isnt the cause. Plan for now is to put 5 15V 1 watt zeners on a tube base I can plug into the existing socket and see what happens. If that is the cause I will readily invest in another tube because I think they look cool too. During transmission (modulation peaks?) the VR tube glow intensity will change and even shift pattern from one part of the tube to others with some hysteresis. This is normal. Arcing is not normal. But note that the glow and shadows might show some structure (kinda shadows and shadow edges) shifting as the current through the VR tube changes and maybe you suspect that is arcing? Tim.- Hide quoted text - - Show quoted text - I put a neon bulb across the dropping resistor, well across a piece of the dropping resistor. I used a photo transistor to couple to my counter. Over a 12 hour peiod I got 10 to 15 hits. With the Zeners in place I havent had any.. First noticed the problem when the plate current meter on my amp went from 0 to full scale just setting on the bench. Bias supply is set up so unless the amp is keyed it has the full -75V on the grids cutting the amp off when keyed it drops to about -45. When I caught it on my storage scope it was about -18v. I like the VR tubes too, now that I am more certain thats whats causing the problem I dont mind ordering a couple more VR tubes. Before I order new ones I am thinking of trying the same monitoring setup again with the tube in place but this time changing the bias adjust pot. That would be the only thing I havent checked. I hate intermittent problems like this. Jimmie |
Thread Tools | Search this Thread |
Display Modes | |
|
|