Paul Burridge wrote:
Hi all, I need to wind 180nH inductor for a parallel tuned circuit I'm building, since the 180nH factory-made chokes I have don't look up to the job power-handling wise. This coil needs to handle about 90mA p-p/ 500mW maximum dissipation sine current and I've allowed 3 ohms for series resistance. Can anyone give me some steer on dimensions, number of turns, core type and so on? Thanks, Here are the basic formulas for air core coils. 3 ohms sounds pretty high for such a small inductance. -- John Popelish |