Old December 9th 03, 10:11 PM
Steve Nosko
 
Posts: n/a
Default

There'something sour here. Way down ...


"Paul Keinanen" wrote in message
...
[snip]

The problem with circuits containing both inductances and capacitances
is that in one kind of reactance, there is a +90 degree phase shift
and the other with -90 degree phase shift. Thus, when these are
combined, they partially cancel each other, producing different
magnitudes and some phase shift between -90 and +90 degrees. If only
the resultant magnitude is used (and the resultant phase is ignored),
this would give the false impression that the inductance changes with
frequency.


I don't quite follow where you are going here. below the self resonant
freq the angle will be +90 (minus a little for what ever resistance is
there).


The rest of this about measuring the energy from DC, I don't think is at all
practical.

[snip] the inductance could be measured in a different way.
... the energy
stored in the inductance is W = I*I*L/2. ...
...cut the DC current...dissipate the energy in some kind of
integrating load across L. Even if there is a significant

capacitance[snip]
...the energy would bounce back
between L and C, but finally it would be dissipated by the external
load. ...
Thus using this measurement method, the value of L would be the same
regardless if C is present or not....

Paul OH3LWR

OK. so then, how do you propose to measure this energy? I don't think
it is practical.


--
Steve N, K,9
d, c. i



 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Coils or specifications needed for Heathkit GD-1B Grid Dip Meter. Bob Equipment 9 August 15th 04 02:42 PM
Coils or specifications needed for Heathkit GD-1B Grid Dip Meter. Bob Equipment 0 August 12th 04 08:36 AM
Coils or specifications needed for Heathkit GD-1B Grid Dip Meter. Bob Equipment 0 August 12th 04 08:36 AM
National SW-3 coil winding data John H. Gindlesberger Boatanchors 0 March 17th 04 07:00 PM
phasing coils Antenna 2 July 25th 03 04:06 AM


All times are GMT +1. The time now is 08:40 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017