In message , Frank Dinger
writes I have a number of transformers and would like to experiement using then at a higher frequency....let say 500 hz and / or higher..... Would they still work?...I am assuming so... Would they run cooler?.... Could anyone foresee any negative effects?.... ========================= Running transformers on a higher freq is fine provided the core can manage the higher freq. During the valve era ,aeronautical radio equipment ran on 400 Hz resulting in smaller and hence lower weight transformers. However running power supply transformers at an AC frequency lower than the one they are designed for might cause the laminated core to overheat. In practice : 50 Hz transformers meant for use in Europe and elsewhere can be readily used in the US and Canada. However transformers designed for 60 Hz having 'marginal cores' could overheat when used on a 50 Hz supply. So equipment with 'wallwarts' purchased in the US ,(apart from being suitable for 117 V only ) I never use on a 50 Hz supply system. Nowadays with much equipment having a switch mode power supply , the frequency / voltage problem no longer exists. Frank GM0CSZ / KN6WH Yes, you can sometimes have serious trouble on 50Hz when the equipment was designed in a 60Hz area. The problem is simply not enough inductance in the transformer for the lower frequency (even though the difference is small). I recall two examples from my work (in the cable TV industry): 1. Hundreds of 50 to 600MHz outdoor repeater amplifiers, line powered (via the coax) at 60VAC. Took far too much current, and all the transformers had to be replaced. 2. Piece of rack equipment. 115V input, multiple output windings. We simply provided a 240-115V step down when we installed it. No problems. One day, new unit, fuse pops after a few seconds. Mains transformer same part number, but different supplier, also slightly fewer laminations. Current went up from 0.2A to 3A. Not an easy fix. There can also be a problem with switch mode power supplies, but the problem is not the frequency. It is the higher inrush current when you switch on. Again, cable TV equipment, had 0.25A mains fuse. Regularly popped fuse on switch-on. Took a slow-blow 1A to stop it, although the steady-state current was only 80mA. I'm not pro-American, but I often think that the world might have been a simpler place if we had all used 115VAC, 60Hz, 525-line TV etc.... Ian. -- |
#2
![]() |
|||
|
|||
![]()
In article le.rogers.com,
"larry" writes: Way back, when I was 7 or 8 years old, (I am 55 now), my dad got me an electric train set....During that Christmas we were at my Grandparents place and they were on 25 hz power....At home we were on 60 hz power... We had to be at home for me to try out my new train set. What has that got to do with this question?... This.... I have a number of transformers and would like to experiement using then at a higher frequency....let say 500 hz and / or higher..... Would they still work?...I am assuming so... Should not be a problem. Designed for 25 Hz operation, they have a lot more iron in the core than those for 50/60 Hz. That means they are HEAVY. [it's a mechanical mounting problem only] Would they run cooler?.... Not any more than audio amplifier power output transformers at the same wattage. Could anyone foresee any negative effects?.... Other than physical mounting places having to be much more sturdy, no problems at all. Aerospace electronics went to 400 Hz (and higher "wild" supply frequencies) some time ago to save WEIGHT. For the same power handling capability, the core size could be smaller for a given core flux desnity in comparison to 60 Hz. You WILL get heating and inordinate core losses and loss of efficiency of power transfer in trying to use a 400 Hz transformer at 60 Hz. You will NOT have any of those problems on getting a lower- frequency transformer to work at a higher frequency. For common transformer iron laminations, the upper end of frequency response...where all the effects others were talking about, would be above, perhaps, 5 KHz to 10 KHz. Those other effects would only begin to show up at that limit frequency, getting worse at higher frequencies. In the old vacuum tube "Hi-Fi" music amplifers, output transformers needed a BIG core cross section to reach down to 30 Hz. The upper end of response was determined primarily by the distributed capacitance of the winding with the most turns, secondarily by the iron alloy of the core. Mutual inductance effects didn't much come into play - regardless of what some instructors talked about in classes to illustrate "points" about mutual inductance. :-) Len Anderson retired (from regular hours) electronic engineer person |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Wanted: Power Supply for TR-4C | Boatanchors | |||
Wanted: Power Supply for TR-4C | Equipment | |||
More free: Power transformers | Boatanchors | |||
Derivation of the Reflection Coefficient? | Antenna |