Home |
Search |
Today's Posts |
#11
![]() |
|||
|
|||
![]()
On Sat, 17 Apr 2004 17:26:15 +0100, John Woodgate
wrote: I read in sci.electronics.design that James Meyer wrote (in ) about 'A neat and compact way to generate RF harmonics...', on Sat, 17 Apr 2004: IOW, the Q without the probe will be higher than the Q when you insert the probe to measure the Q. Use an inductive current pick-off. That how the Marconi Instruments 1245 series Q-meters work(ed). I can recall using one of those, some little time back. Anybody have the schematic diagram for it? Barry Lennox |