Home |
Search |
Today's Posts |
#11
![]() |
|||
|
|||
![]()
I read in sci.electronics.design that James Meyer
wrote (in ) about 'A neat and compact way to generate RF harmonics...', on Sat, 17 Apr 2004: On Sat, 17 Apr 2004 17:26:15 +0100, John Woodgate posted this: I read in sci.electronics.design that James Meyer wrote (in ) about 'A neat and compact way to generate RF harmonics...', on Sat, 17 Apr 2004: IOW, the Q without the probe will be higher than the Q when you insert the probe to measure the Q. Use an inductive current pick-off. That how the Marconi Instruments 1245 series Q-meters work(ed). Nevertheless, *ANY* method used to probe the field associated with the resonator will load the resonator and degrade the Q. IIRC, the Marconi unit used a 10 nH inductor (maybe less) made of a short length of silver wire, gold-plated to eliminate sulfide attack. The effect on Q would be minimal in the extreme. -- Regards, John Woodgate, OOO - Own Opinions Only. The good news is that nothing is compulsory. The bad news is that everything is prohibited. http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk |