Jim Thompson wrote:
On Wed, 21 Jul 2004 21:48:28 +0200, J M Noeding wrote: Hi It seems to be some problem to build equipment to measure over +35...40dBm IP3, and xtal filters seem to cause intermodulation problem with this level What I am after is constructions to build which works to measure higher IP3. Would also be interested to see IP3 measurements for xtal filters 73, Jan-Martin --- J. M. Noeding, LA8AK, N-4623 Kristiansand http://home.online.no/~la8ak/c.htm Padded-down spectrum analyser ?? 36 to 63V P-P into 50 ohms ain't easy ;-) ...Jim Thompson IM3 is generally projected up from measurements made at much lower power levels -- on most RF circuits running at useful power levels the 3rd-order IM products vary as the cube of power, so you measure the power-in/IM3-out levels at lower input levels and plot it all on a graph. Not that I can answer the OP's question, and padding down the signal is probably going to be a featured part of any setup. -- Tim Wescott Wescott Design Services http://www.wescottdesign.com |