| Home |
| Search |
| Today's Posts |
|
#26
|
|||
|
|||
|
I read in sci.electronics.design that john jardine
wrote (in k) about 'Diode and very small amplitude high frequencies signals', on Sat, 5 Feb 2005: Test on a 1N4148. ForwardV DiodeR +50mV 8megs. +30mV 9megs. +20mV 10megs. +10mv 12megs. +5mV 21megs. ReverseV -5mV 21megs. -10mV 30megs. -30mV 270megs. How did you measure the resistance? Is it an incremental resistance (slope of the V/I curve at the data point) or the slope of a line joining the origin to the data point on the curve. -- Regards, John Woodgate, OOO - Own Opinions Only. The good news is that nothing is compulsory. The bad news is that everything is prohibited. http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk |