Home |
Search |
Today's Posts |
#5
![]() |
|||
|
|||
![]() "John A" wrote in message ... See http://homepage.eircom.net/~ei9gq/spec2.jpg for a screen shot. Assume the center is a zero frequency. Looks suspiciously like LO IF overload to me. Try a 10 dB pad in the mixer output -- should be easy to get at. As you mentioned there may be a mixer balance problem. I thought the HP8558B used to plug in a HP141T display, but found a pic on the web, and it appears to be a later generation. I have occasionally seen the results of transmitting directly into those old spectrum analyzers, and in the 70s, it was $1,000 for the attenuator, and $1,000 for the mixer. Sure hope you don't have that kind of problem. Regards, Frank |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Daiwa MR750 Rotator Info Needed | Antenna | |||
Heathkit SB-200 Amplifier Problem Help? | Boatanchors | |||
Spectrum Analyser CRT drive problem | Homebrew | |||
Help Needed on Halli SX110 | Boatanchors | |||
spectrum analyser | Homebrew |