| Home |
| Search |
| Today's Posts |
|
#2
|
|||
|
|||
|
Roberto IZ5FCY wrote:
Hello to everybody. I would want to use a pair or quad tetrode (4-400a or 4cx250/350) as GG triode for AB/C class operations. I don't remember where I have read that only the control grid had physically push to ground, while the others grid(s) was electrically floating and connected to ground through of the capacitors.... Can you help me with schemas, links and suggestions? Many thanks in advance..and sorry for bandwidht... Roberto IZ5FCY AFAIK a tetrode in grounded grid doesn't give you much more (if any) gain than a triode in grounded grid, but you still need all the special care and feeding of the screen. So why not just use triodes? Better yet, why not use the tetrodes in common-cathode service, and get 1000 watts out for 1-10 watts in? -- Tim Wescott Wescott Design Services http://www.wescottdesign.com Posting from Google? See http://cfaj.freeshell.org/google/ |