Hi,
I am using a couple of 45MHz crystal filters in my first IF amp. Has anyone any experience of using these, and give me any advice on problems they encountered. I think I have a problem with screening, as they require 700 Ohms termination resisistance. When the manufacturers spec a termination resistance, do the filters themselves look like say 700 Ohms, or do I need to set this externally with a resistance? Best regards, John. |
|
#2
|
|||
|
|||
|
On Wed, 22 Mar 2006 10:29:56 +0000, John Wilkinson
wrote: Hi, I am using a couple of 45MHz crystal filters in my first IF amp. Has anyone any experience of using these, and give me any advice on problems they encountered. I think I have a problem with screening, as they require 700 Ohms termination resisistance. When the manufacturers spec a termination resistance, do the filters themselves look like say 700 Ohms, or do I need to set this externally with a resistance? The filters -do not- look like 700 ohm, at least not in the stopband. Unless a filter has a dissipative loss, the only way it can attenuate is by reflecting out-of-band signal(s). To do this, it must be highly mismatched. The termination impedance is what the filter needs to see to perform as specified. You must set this either with a resistance and/or an amplifier designed to present this impedance to the filter. |
|
#3
|
|||
|
|||
|
Hi John:
terminations are an integral part of a filter design. there are a few usual or widespread impedances in use. actually the impedance has a marked effect on the filter's bandwidth, more than on shape. the narrower the filter, the lower the impedance. much more critical is the screening problem: the filters's cases must be very well grounded! any leakage here goes around the filter.it's not enough to solder to ground the relevant lead: you have to add a strap from the case to ground. Saandy 4Z5KS John Wilkinson wrote: Hi, I am using a couple of 45MHz crystal filters in my first IF amp. Has anyone any experience of using these, and give me any advice on problems they encountered. I think I have a problem with screening, as they require 700 Ohms termination resisistance. When the manufacturers spec a termination resistance, do the filters themselves look like say 700 Ohms, or do I need to set this externally with a resistance? Best regards, John. |
| Reply |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Forum | |||
| FS: Ceramic / Crystal / Mechanical filters | Swap | |||
| FA: Kenwood Crystal Filters & Misc | Swap | |||
| crystal ladder filters | Homebrew | |||
| FS: New Crystal Filters $25.00 | Boatanchors | |||
| FS: New Crystal Filters $25.00 | Swap | |||