Home |
Search |
Today's Posts |
#10
![]() |
|||
|
|||
![]()
Methylene chloride was used as a cleaning agent where I work; the
employees used it in a fume hood, wore gloves, goggles and a respirator and werere given medical exams annually. Truly nasy stuff - thankfully we replaced it with Hexane ....... no kidding, I couldn't make this stuff up! On Fri, 20 Feb 2004 05:46:31 GMT, "Pete KE9OA" wrote: I agree......................I only use it outdoors. A chemist friend of mine once told me that if it get on your skin, it can diffuse into your body and dissolve the fatty tissues, such as you liver, etc. The local Ace hardware store discontinued that item because of the inherent dangers. I think that about the only way you can buy it nowadays is through a company such as Cope Plastics, and that would be by the quart, at the very minimum. A very bad chemical, but the best thing that I have run into for fusing plexiglass. Still, I wouldn't recommend it to anybody that didn't have experience in handling this type of chemical. As an aside, Methylene Chloride is one of the active ingredients in Zip Strip, the paint and varnish stripper. Zip strip is handy for stripping the photo resist from printed circuit boards. Pete "helmsman" wrote in message .. . "Pete KE9OA" wrote: Those things are pretty hard to open up............I had the roughest time with the one for my FGR100, but if you are careful, a utility razor can do the job. Gluing it back together is another thing. Probably, the safest adhesive is epoxy. There are better agents (Methylene Chloride), but these are very dangerous. Pete "starman" wrote in message ... Pete KE9OA wrote: I've never run into an external power supply that didn't need some work to optimize it for noise suppression. Even the AOR7030's power supply benefited from a little extra work. For about 2 dollars worth of components, any power supply can be made to be quiet. Connect .01uF caps across each of the rectifier diodes, and bypass each leg of the power transformer's secondary to ground with 1uF non-polarized caps to ground, and you are all set. Make sure that you derate the 1uF units to at least twice the peak to peak output voltage of the transformer. There is no such thing as a good wall wart, from Radio Shack or anybody else. Even the relatively expensive Power One frame supplies need these add-ons. The reason that these manufacturers don't do this in the first place is because they don't have to subject their units to stringent EMC testing. I hope this helps. Pete, What is your preferred method for cutting the wall wart open? -----= Posted via Newsfeeds.Com, Uncensored Usenet News =----- http://www.newsfeeds.com - The #1 Newsgroup Service in the World! -----== Over 100,000 Newsgroups - 19 Different Servers! =----- Methylene Chloride is listed as a Poison. And is an inhalation hazard that is heavier than air. It can KILL you. Grundig has gotten in touch with me, we shall see what happens. |