I have an R-390(non-A) that recently developed a problem. When I first turn
it on, both audio level and RF level (carrier meter) are weak. DC voltage
at the "regulated" test point (J601) on the side of the AF subchassis is
only about 65 to 80 VDC, with less than 0.005 VAC ripple. After "warming
up" for another 5 to 8 minutes, both audio and carrier levels abruptly jump
to "full strength", and regulated DC is up around its rated 180 VDC.
However, audio is distorted with heavy hum, and there's about 4.5 VAC at the
regulated DC test point. Both the high voltage electrolytic (C101) and
regulated DC filter (C103) capacitors check out within spec. Any other
likely culprits to start checking out?

Thanks!
Ken, WB0OCV


 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Amateur Radio Newslin(tm) Report 1385 – February 27, 2004 Radionews Broadcasting 0 March 5th 04 01:26 AM
Amateur Radio Newslin(tm) Report 1385 – February 27, 2004 Radionews General 0 March 4th 04 09:52 PM
Amateur Radio Newslin(tm) Report 1385 – February 27, 2004 Radionews Dx 0 March 4th 04 09:52 PM
Amateur Radio Newslin(tm) Report 1385 – February 27, 2004 Radionews Dx 0 March 4th 04 09:52 PM
stuff for all hams [email protected] General 0 December 19th 03 07:31 PM


All times are GMT +1. The time now is 09:28 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017