Thread: Egg insulators
View Single Post
  #3   Report Post  
Old September 4th 04, 10:12 PM
J. Mc Laughlin
 
Posts: n/a
Default

Dear Ken: The wire loops overlap. The insulator is in compression not
tension. If the insulator breaks, the wire is still, sort of, supported.
The "egg" insulators that I have used did not have a groove that went
all of the way around.
For reference: about how large are your insulators?
73 Mac N8TT

--
J. Mc Laughlin; Michigan U.S.A.
Home:
"Ken" wrote in message
...
I just picked up some small egg insulators and have a question.

I had assumed that the wire went through the hole, was routed back in
the groove to the far end of the insulator, and was twisted back on
the standing part. The two loops overlap, as it were. However, the
groove for the wire continues all around the egg, including the near
end of the insulator opposite the standing part. This suggests some
kind of fancy wire routing is expected.

How come they continue the groove all around? Do these sometimes get
used with the insulator in tension and the loops not overlapping?

Ken KC2JDY


Ken
(to reply via email
remove "zz" from address)