Tarmo Tammaru wrote:
Now for Cecil 1. ZL = 50 - j400. VF=1.62, VR=1.56, SWR=53, PF=1.33W,
PR=1.24W.

Now for Cecil 2. ZL=50-j400, BUT ZS= 0 + J400. VF=11.2, VR=10.9, SWR=73.7,
PF=64W, PR=60.6W. I am at such a high impedance here, that I suspect the 10K
sampling resistors are loading down the circuit somewhat. (I might try 100K
instead).

Note that there is absolutely nothing explicit in the circuit that has
anything to do with transmission lines. All components are perfect; there
are no stray inductances or stray capacitors.


Chipman alludes to such a "phenomenon of resonance" in Chapter 10,
"Resonant Transmission Line Circuits". For instance, at a conjugate match
point where 100+j100 is seen looking in one direction and 100-j100 is
seen looking in the opposite direction, there seems to be a *localized*
exchange of extra energy between +j100 and -j100 that can adversely affect
the value indicated by an SWR meter placed between those two values.
--
73, Cecil http://www.qsl.net/w5dxp