Someone asked in a Technician license class *why* 450 ohm window line
has much lower loss than an equal length of 50 ohm coax does at the
same frequency. The instructor knew that it is true, but could not
say why. I have an idea about the answer, and would like to know how
I'm doing. I'm one of those hams who is NOT a EE, so I'm trying to
work this out based on high school physics, which at least back in
1964, covered AC but not RF.

I observe that at higher Z, the voltage is higher while the current is
lower for a given power level. Ohmic losses are proportional to the
square of the current. This is the same reason that long distance
power transmission is done at high voltage.

For example, 100 W through 50 ohms is 1.4A @ 70V, while 100W through
450 ohms is 0.47A @ 212V. That is, 9 times the impedance results in
1/3 the current, which results in 1/9 the ohmic loss through the
resistance of the transmission line.

I expect that we also need to account for the difference in R
resulting from different conductor diameter and skin effect, and
probably difference in the dialectrics, neither of which I yet know
how to calculate. Apart from those factors, is my explanation based
on the current vs. impendance:

1. Basically correct?

2. On the right track, but oversimplified, and thus not much use?

3. Completely out in left field?

Thank you.

--
73 DE KW6H Chris Jewell Gualala CA USA
  #2   Report Post  
Old May 2nd 07, 11:39 PM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Dec 2006
Posts: 1,169
Default Why are hi-Z transmission lines low loss?

Chris Jewell wrote in
:

Someone asked in a Technician license class *why* 450 ohm window line
has much lower loss than an equal length of 50 ohm coax does at the
same frequency. The instructor knew that it is true, but could not
say why. I have an idea about the answer, and would like to know how
I'm doing. I'm one of those hams who is NOT a EE, so I'm trying to
work this out based on high school physics, which at least back in
1964, covered AC but not RF.

I observe that at higher Z, the voltage is higher while the current is
lower for a given power level. Ohmic losses are proportional to the
square of the current. This is the same reason that long distance
power transmission is done at high voltage.

For example, 100 W through 50 ohms is 1.4A @ 70V, while 100W through
450 ohms is 0.47A @ 212V. That is, 9 times the impedance results in
1/3 the current, which results in 1/9 the ohmic loss through the
resistance of the transmission line.

I expect that we also need to account for the difference in R
resulting from different conductor diameter and skin effect, and
probably difference in the dialectrics, neither of which I yet know
how to calculate. Apart from those factors, is my explanation based
on the current vs. impendance:

1. Basically correct?

2. On the right track, but oversimplified, and thus not much use?

3. Completely out in left field?

Thank you.


Chris,

Your explanation is basically correct if your statements depend on the
assumption that both transmission lines are of the same type and
constructed of the same conductors.

In a practical balanced line, most of the loss at HF is in ohmic loss,
the heat generated when current flows through the conductors, and your
workup applies.

In most practical coaxial lines, most of the loss at HF is in ohmic loss,
the heat generated when current flows through the conductors. It turns
out that most of that loss is in the centre conductor (the RF resistance
of the inside of the outer conductor is typically lower than the RF
resistance of the outer of the inner conductor).

So, back to your unstated assumption of same type and same conductors,
when you make the appropriate corrections for coaxial and balanced line
types, then what you have said applies. Having said that, balanced lines
with extremely close spacing (Zo less than about 100 ohms) suffer from an
additional mechanism affecting effective conductor resistance, it is the
proximity effect that causes current to not flow evenly in the skin as it
would for larger spacings.

The mechanism as you have stated it is broadly correct, but it needs to
include a statement of assumptions, and liberal use of words like "most"
to cover the exceptions. It is easier to make the general statement that
"for the same conductors, an air spaced two wire balanced line of 600
ohms characteristic impedance will have close to half the loss of such a
line of 300 ohms", and your explanation applies.

Owen


, and your workup applies
  #3   Report Post  
Old May 3rd 07, 12:12 AM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 644
Default Why are hi-Z transmission lines low loss?

On May 2, 3:16 pm, Chris Jewell wrote:
Someone asked in a Technician license class *why* 450 ohm window line
has much lower loss than an equal length of 50 ohm coax does at the
same frequency. The instructor knew that it is true, but could not
say why. I have an idea about the answer, and would like to know how
I'm doing. I'm one of those hams who is NOT a EE, so I'm trying to
work this out based on high school physics, which at least back in
1964, covered AC but not RF.

I observe that at higher Z, the voltage is higher while the current is
lower for a given power level. Ohmic losses are proportional to the
square of the current. This is the same reason that long distance
power transmission is done at high voltage.

For example, 100 W through 50 ohms is 1.4A @ 70V, while 100W through
450 ohms is 0.47A @ 212V. That is, 9 times the impedance results in
1/3 the current, which results in 1/9 the ohmic loss through the
resistance of the transmission line.

I expect that we also need to account for the difference in R
resulting from different conductor diameter and skin effect, and
probably difference in the dialectrics, neither of which I yet know
how to calculate. Apart from those factors, is my explanation based
on the current vs. impendance:

1. Basically correct?

2. On the right track, but oversimplified, and thus not much use?

3. Completely out in left field?

Thank you.

--
73 DE KW6H Chris Jewell Gualala CA USA



Owen seems to have covered it pretty well. Here are a few more
related observations:

To a pretty good approximation, the matched-line loss in dB/100 feet
is given by:

A100 = 4.34*Rt/Zo + 2.78*f*sqrt(r.d.c.)*Fp

where A100 is loss, dB/100ft
Rt is the RF resistance of the conductors in ohms/100 feet (see
below)
Zo is the nominal line impedance, ohms
f is the operating frequency, MHz
r.d.c. is the relative dielectric constant of the dielectric between
the conductors
Fp is the dielectric's power factor at frequency f

Rt for round copper conductors is given for coax by
Rt = 0.1*(1/d + 1/D)*sqrt(f)
where d and D are the inner conductor diameter and the inside diameter
of the
outer conductor, both in inches
and for two-wire balanced line,
Rt = 0.2*sqrt(f)/d
where d is the diameter of either conductor, inches. That doesn't
account for the proximity effect Owen mentioned.

Conductor loss is increased by stranding and by brading. Smooth solid
conductors give lowest loss in almost all circumstances.

It turns out that if there is negligible loss in the dielectric, the
coaxial line loss for a given D will be minimized for D/d = 3.59,
independent of the dielectric you put in. If it's air dielectric, the
impedance for minimum loss is about 76 ohms, but if you fill the line
with solid polyethylene, the impedance is a little above 50 ohms. In
cases where the power handling capacity of the line is limited by
power dissipation and not by arc-over (which is almost certainly true
unless you're dealing with short, high-power pulses), the lowest line
loss will give you very close to the coolest conductors, so if you use
solid-dielectric coax, 50 ohms is a good value with respect to line
loss. The loss-vs-impedance has a rather broad peak, though, so it's
not critical.

If the line is operating into a load not close to the Zo of the line,
there is additional loss. In a qualitative way, you can see that by
realizing that standing waves create areas of high current, and as you
noted, the loss goes up as the square of the current. The squared
effect means that the low loss in the areas of low current don't
cancel out the high loss in the areas of high current. To be accurate
about it, you need to integrate the net current squared times the
resistance per unit length, along the length of the line.

Cheers,
Tom

  #4   Report Post  
Old May 3rd 07, 01:49 AM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Mar 2007
Posts: 3,521
Default Why are hi-Z transmission lines low loss?

Chris Jewell wrote:
1. Basically correct?


In addition to the obviously lower matched line losses, a
high-Z line has an additional advantage - lower average
SWRs with non-resonant antennas. For instance, a 5000 ohm
full-wave dipole will have an SWR of 100:1 using 50 ohm coax.
It will have an SWR of 8.3:1 using 600 ohm open-wire line.
--
73, Cecil http://www.w5dxp.com
  #5   Report Post  
Old May 3rd 07, 02:04 AM posted to rec.radio.amateur.antenna
art art is offline
external usenet poster
 
First recorded activity by RadioBanter: Sep 2006
Posts: 1,188
Default Why are hi-Z transmission lines low loss?

On 2 May, 15:16, Chris Jewell wrote:
Someone asked in a Technician license class *why* 450 ohm window line
has much lower loss than an equal length of 50 ohm coax does at the
same frequency. The instructor knew that it is true, but could not
say why. I have an idea about the answer, and would like to know how
I'm doing. I'm one of those hams who is NOT a EE, so I'm trying to
work this out based on high school physics, which at least back in
1964, covered AC but not RF.

I observe that at higher Z, the voltage is higher while the current is
lower for a given power level. Ohmic losses are proportional to the
square of the current. This is the same reason that long distance
power transmission is done at high voltage.

For example, 100 W through 50 ohms is 1.4A @ 70V, while 100W through
450 ohms is 0.47A @ 212V. That is, 9 times the impedance results in
1/3 the current, which results in 1/9 the ohmic loss through the
resistance of the transmission line.

I expect that we also need to account for the difference in R
resulting from different conductor diameter and skin effect, and
probably difference in the dialectrics, neither of which I yet know
how to calculate. Apart from those factors, is my explanation based
on the current vs. impendance:

1. Basically correct?

2. On the right track, but oversimplified, and thus not much use?

3. Completely out in left field?

Thank you.

--
73 DE KW6H Chris Jewell Gualala CA USA


I think you did pretty good Chris, Basically it is correct, it is of
use and not out in left field.Tecnician level did you say?
Problem is that you asked what the time is whereas they wanted
you to pose the question how to make a watch.
Art

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Coils and Transmission Lines. Reg Edwards Antenna 35 April 4th 06 01:36 PM
New program. Coils and Transmission Lines. Reg Edwards Equipment 0 April 2nd 06 05:18 AM
New program. Coils and Transmission Lines. Reg Edwards Homebrew 0 April 2nd 06 05:16 AM
Coils are transmission lines Reg Edwards Antenna 22 March 19th 06 03:38 AM
parallel transmission lines Hal Rosser Antenna 0 July 31st 04 09:23 AM