Owen Duffy wrote:
"Rick (W-A-one-R-K-T)" wrote in news ![]() On Sun, 15 Jul 2007 17:23:13 +0000, Walter Maxwell wrote: This topic has aroused my curiosity. As a grounding device, why would a solid rod be better than a hollow pipe, except for the current carrying capability? Good afternoon, Walt. The thing is, the current carrying capability for transient events like lightning strikes should be about the same for the same diameter pipe or rod, since most of the current is carried in skin effect anyway. I think that is flawed thinking. A lighning down conductor needs to carry something like 20kA for 100ms, so it needs to be substantial enough that it doesn't melt and remains in place to protect against the next strike. Owen The fusing/melting current for 1/2" copper pipe is probably well above 20kA, even for 100ms pulses. A more interesting potential failure mode might be from the mechanical forces due to the magnetic field. (see, e.g., quarter shrinking or can-crushing) |
#2
![]() |
|||
|
|||
![]()
Jim Lux wrote in
: Owen Duffy wrote: "Rick (W-A-one-R-K-T)" wrote in news ![]() On Sun, 15 Jul 2007 17:23:13 +0000, Walter Maxwell wrote: This topic has aroused my curiosity. As a grounding device, why would a solid rod be better than a hollow pipe, except for the current carrying capability? Good afternoon, Walt. The thing is, the current carrying capability for transient events like lightning strikes should be about the same for the same diameter pipe or rod, since most of the current is carried in skin effect anyway. I think that is flawed thinking. A lighning down conductor needs to carry something like 20kA for 100ms, so it needs to be substantial enough that it doesn't melt and remains in place to protect against the next strike. Owen The fusing/melting current for 1/2" copper pipe is probably well above 20kA, even for 100ms pulses. A more interesting potential failure mode might be from the mechanical forces due to the magnetic field. (see, e.g., quarter shrinking or can-crushing) Hi Jim, I note the "probably" in your comment, and the "dunno" in N5MK's response. The uncertainty in my statement is over the exact lightning scenario, they vary, and the circuit response (ie current waveshape, amplitude, duration, ringing etc) depend on the specific excitation and circuit elements (parameters of the down conductor, nature of the earth system, ground, environment etc). As far as supposition as to the fusing current for conductors, that is determinable for a given scenario. I have at hand the Protective Earthing Code of Practice published by the Electricity Authority of NSW June 1975 and it shows that a 35mm^2 copper conductor has a fault current withstand of 20kA for 100ms. (I have considered implementing the underlying formulas in an online calculator.) N5MK stated "A #10 wire can handle that job". If he is talking copper, I understand that #10 means 2.5mm diameter, or ~5mm^2, or less than 15% of the recommended conductor csa for the stated scenario. I am not familiar with your water pipe sizes. If it were, say, a half inch diameter #19, it has a CSA of around 35mm^2, so the #10 wire should melt before the pipe electrode, thus protecting the pipe electrode from failure. Yes, mechanical forces are also relevant to lightning conductors, but my comment was about the fusing current. In this part of the world there is an Australian Standard (AS1768) relating to lightning protection, there may be a similar standard or "code" in other jurisdictions, and they would not be a bad place to start in understanding lightning protection and designing a protection scheme. Another source of information is to walk around a mobile phone base station and look at the earthing system from the outside. It is even more enlightning (no pun) to look inside. These things withstand lightning events quite well. Are they over engineered? Probably not, they do suffer damage from time to time. It is my view that there is a significant risk that an inadequate lightning protection scheme may be much worse than doing nothing. Owen |
#3
![]() |
|||
|
|||
![]()
Walter Maxwell wrote:
big snip This topic has aroused my curiosity. As a grounding device, why would a solid rod be better than a hollow pipe, except for the current carrying capabilitY? Walt, W2DU I would expect that a driven, solid rod would be in more intimate contact with the earth while a water drilled pipe would have lots of surface air gaps, at least initially. After some period of time the gaps would fill in in most dirt and I wouldn't expect there to be any difference. -- Jim Pennino Remove .spam.sux to reply. |
#4
![]() |
|||
|
|||
![]() "Walter Maxwell" wrote in message ... This topic has aroused my curiosity. As a grounding device, why would a solid rod be better than a hollow pipe, except for the current carrying capabilitY? Walt, W2DU I doubt that there would be any real differance to start with. The pipes are thin enough they would be hard to drive in the ground and after a while they would rust out sooner. |
#5
![]() |
|||
|
|||
![]()
I doubt that there would be any real difference to start with. The pipes
are thin enough they would be hard to drive in the ground and after a while they would rust out sooner. ================================================== Copper ....rusting ? ........... must be veeeery acidic soil .....perhaps in the backyard of a chemical plant ? Frank GM0CSZ / KN6WH |
#6
![]() |
|||
|
|||
![]() "Rick (W-A-one-R-K-T)" wrote in message news ![]() How about a 10-foot length of copper water pipe, connected to a garden hose with an adapter fitting (as simple as a short length of another garden hose, clamped to the pipe with radiator hose clamps). Run water down the pipe and stick the pipe in the ground, pulling it up and pushing it down so that the water helps drill the hole in a manner just like you described. Keep it up until it has gone in as far as it will go, then (if it hasn't gone in the whole 10 feet) cut it off and solder a copper cap on the end. You end up with a hollow pipe in the ground instead of a solid steel rod, but everything I read about lightning strikes says that the vast majority of the current flows in skin effect anyway. Copper clad steel rods are made precisely because the copper cladding on the outside skin is what conducts the current anyhow. So it makes no difference whether you utilize copper pipe or copper clad steek rods. To drive copper pipe down I use a length of about 1 foot of aluminum tubing connected to a garden hose (tubing fits in garden hose and is clamped tightly, Aluminum tubing slides into copper pipe. The rubber hose goes up against the copper tubing rather tightly to make a quasi seal, it'll be enough although some little bit of spray from backpressure will come out. Turn on the faucet and the copper pipe will very quickly begin to drive itself into the ground. Enough slurried wet soil mix will compact around the pipe to make a good earth ground contact but I usually let the hose saturate the ground area around it for about a half hour after so the voids fill in. Bill KC9CS http://home1.gte.net/res0958z/ |
#7
![]() |
|||
|
|||
![]()
If you already have the copper pipe and you can get it in the ground I
doubt you will ever notice the difference. I live on red clay in the Piedmont region of North Carolina. There are times when I could push three feet of #3 rebar in the ground with one hand. At this time of year I doubt I could drive it more than about 6 inches! Two years ago I had a pro install lightning rods. They added two galvanized 1/2 inch ground rods at diagonal corners of the house. They then tied one of these to the power ground. They also tied one corner to my tower with a massive clamp. A whole house surge protector was installed at the power panel. I have since added a vertical antenna (28 feet) with 35 radials 70 feet long. I have not had a lightning strike since they did the install. I think the charge bleeds off before it builds up to a serious level. Before the install I was averaging about $500 a year in VCRs, TV sets, Stereos, etc. The best advice I can offer is to use conventional materials available in your area, meet code and keep your insurance company satisfied. BTW, I still unplug antennas and rotors when not in use! John Ferrell W8CCW "Life is easier if you learn to plow around the stumps" |
#8
![]() |
|||
|
|||
![]()
I have used hollow copper pipe for years.
I have one 10 foot copper clad steel ground rod which I used to drive the pilot hole into the ground, then hauled it out using a car jack. I then put a copper pipe in the hole. The copper pipe has 1/4 inch holes drilled along its length for the bottom three feet. I used 3 pipes and the copper clad rod as a system of four tied together with #2 copper which is soldered to all four pipes. At first the copper pipes are loosely set into the hole left by the steel rod, but after a while the ground settles and they are firmly implanted. Every year I take a mixture of water and epsom salts and pour it down the hollow pipes. I cannot see what is happening under the ground, but I consider my ground system to be as good as can be hoped for. I have run a couple marconi's without radials using the system and found their performance 'pleasing'. One was an 80m folded marconi -- about 50 ft of it vertical, and the rest folded back at about 45 degrees. It was a great performer and a chum of mine to whom I gave the design has worked all continents and most countries on it. The ground, of course, is the secret. The system has been in place for 24 years. four years ago I jacked one of the pipes out just to see about all these rumors of corrosion but it was fully intact. I steel-wooled it, then put it back in and resoldered it to the system. The pipe was cheaper than the ground rod although that was quite a while back. I say go for it! Irv VE6BP |
#9
![]() |
|||
|
|||
![]()
I use 4 foot to 8 foot long, half inch dia., copper pipe put into the
ground with the use of a water hose clamped to the top of the pipe and a pump - this hydraulically drills the pipe into the soil... They are laid out in a grid around the towers and along the back side of the shack with 16 feet separation... They are all interconnected with bare copper #2 gauge, stranded ground wire (mostly) which is slit into the ground an inch or so to keep it away from the mower blades... All of this creates a large area of metal in contact with the soil.. All of this agonizing over contact of hydraulically driven pipe versus pounded stakes, etc., etc., amounts to counting the number of angels dancing on the head of a pin... Just get in as many ground pipes/ stakes as you can on 16 foot centers, interconnect them in a grid with bare wire slit into the soil, run heavy gauge wire from the stake just outside of wall of the house/shack to the buss bar behind the radio, and be happy... I also competely isolate the radios and amps when they are not in use... denny / k8do |
#10
![]() |
|||
|
|||
![]()
On Tue, 17 Jul 2007 04:48:48 -0700, Denny wrote:
I use 4 foot to 8 foot long, half inch dia., copper pipe put into the ground with the use of a water hose clamped to the top of the pipe and a pump - this hydraulically drills the pipe into the soil... They are laid out in a grid around the towers and along the back side of the shack with 16 feet separation... They are all interconnected with bare copper #2 gauge, stranded ground wire (mostly) which is slit into the ground an inch or so to keep it away from the mower blades... All of this creates a large area of metal in contact with the soil.. All of this agonizing over contact of hydraulically driven pipe versus pounded stakes, etc., etc., amounts to counting the number of angels dancing on the head of a pin... Just get in as many ground pipes/ stakes as you can on 16 foot centers, interconnect them in a grid with bare wire slit into the soil, run heavy gauge wire from the stake just outside of wall of the house/shack to the buss bar behind the radio, and be happy... Like Denny I have a lot of ground rods (32 or 33) in a network CadWelded (TM) to over 600 feet of bare #2 copper wire that ties into the station forming a single point ground or as near to it as I can get. The coax shields are grounded at the top and bottom of the tower as well as to a ground plate where they enter the house. I also competely isolate the radios and amps when they are not in use... Unlike him I rarely disconnect anything for several reasons. The first is the stuff is just too difficult to get to. The second is, I'm lazy and although I could disconcert the station when not in use it takes a good 10 to 15 minutes to get things hooked back up. Typically I want to turn it on, listen, and then operate if the bands are open or shut down if not. In addition, nature threw me a curve a bit over 3 months ago making it very difficult for me to get into places like behind the rigs to disconnect things although I hope to be able to get back in there and up the tower again before long. One other thing and it may be, and probably is due to luck, but with an average of three verified direct hits on the tower per year I've had no damage to any rig since finishing up the ground system. Roger (K8RI) denny / k8do |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Building a Solid Copper Ground Pipe {Tube} with an Solid Iron Core. - Also - Water Drilling a Solid Copper Pipe for a Ground Rod. | Shortwave | |||
Building a Solid Copper Ground Pipe {Tube} with an Solid IronC... | Shortwave | |||
Cold Water Pipe Ground? | Antenna | |||
Ground rod or water pipe? | Antenna | |||
Antenna Tuner/Coupler Ground ... Hot Water Pipe? | Antenna |