#41
|
|||
|
|||
"Quarter wave ground mounted radials are a waste of wire."
"Richard Harrison" wrote in message ... Dave wrote: "You don`t even need reflections. A properly terminated piece of wire has a different current at every point along the wire." Instantaneous values, of course. But, proper termination means no reflection. The only source of variation along a line other than attenuation is reflection. In a uniform line, attenuation causes a steady decline of energy as energy travels. With a lossless line, properly terminated, variation of rnergy along a line is only the phase produced instantaneois values along the line. These are resolved during the period of a cycle by the root mean square calculation. Best regards, Richard Harrison, KB5WZI and what is wrong with instantaneous values? lacking a requirement to talk in peak, phasor, rms, or some other averaging method it is perfectly valid to assume instantaneous measurements. and if I remember right we were talking of measuring current, not energy. and time is a valid parameter when measuring current, just hook up your o-scope and measure away... measure that current on each end of a wire, or coil, or coax, with a dual trace scope and see the difference! throw away that silly-wire-reader thing and get back to the basics. get a pulse generator and build yourself a reflectometer and make use of those reflections! |
#42
|
|||
|
|||
"Quarter wave ground mounted radials are a waste of wire."
Dave wrote:
and what is wrong with instantaneous values? Nothing if presented as part of the context, confusing if not since most people would assume the context is RMS. Do I have 110v AC in my house? You can argue that the answer is "no" but you would need to state the context. -- 73, Cecil http://www.w5dxp.com |
#43
|
|||
|
|||
"Quarter wave ground mounted radials are a waste of wire."
Richard Harrison wrote: Dave wrote: "You don`t even need reflections. A properly terminated piece of wire has a different current at every point along the wire." Instantaneous values, of course. But, proper termination means no reflection. The only source of variation along a line other than attenuation is reflection. The only electromagnetic currents 'flowing' on a transmission line are the currents which result from the reflected and/or the forward electromagnetic waves. Neither of these currents varies periodically along the line (except as noted, instantaneously). 73, ac6xg |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
"meltdown in progress"..."is amy fireproof"...The Actions Of A "Man" With Three College Degrees? | Policy | |||
Ground Plane construction vs pre-printed "protoboards" | Homebrew | |||
"Can twisted wire replace shielded wire?" | Shortwave |