One last question. Is the diameter of the traps at different frequencies
that important and why? They tend to be larger towards top band. Thanks "Owen Duffy" wrote in message ... "Bryan" wrote in : ... cutters. Most coaxial cables exhibit a capacitance of about 30pF/ft, 50 ohm cables with solid PE dielectric ALL exhibit a capacitance of about 30pF/ft. It is not a coincidence, C/unit length, Zo and velocity factor are all related. That method of estimating the capacitive reactance of an o/c stub (for that is what you actually have) is only accurate for very short stubs. Capacitors fabricated from coaxial transmission line are often much lossier that quality fixed capacitors, so they should be used with care. Owen |