John Smith wrote:
Say I had a situation where I must use a ground wire which IS an appreciable percentage of a wavelength ... and don't wish it to radiate. Could I accomplish this by using coax as the ground-wire and choking the outer braid by sufficient windings on a toroid core, and grounding the center conductor and the braid to earth though good and deep grounding spikes or wires? Offhand, I would say you could accomplish a DC ground that way but not an RF ground and not much lightning protection. -- 73, Cecil http://www.w5dxp.com |
#2
![]() |
|||
|
|||
![]()
Cecil Moore wrote:
... Offhand, I would say you could accomplish a DC ground that way but not an RF ground and not much lightning protection. I suspect you to be correct; a "free ride" is just too much to hope for in these times. Well, even a dc/60hz ground which does not radiate rf can be useful. Regards, JS |