On Thu, 16 Oct 2008 20:31:56 GMT, "Jerry"
wrote: "Jeff Liebermann" wrote in message .. . On Thu, 16 Oct 2008 17:17:05 GMT, "Jerry" wrote: Will the taped end will not leak with 80 PSI air in the conduit? Jerry KD6JDJ Well, if it does leak, the sand above the duct tape will dribble down into the 3/4" conduit creating a rather awkward clean up exercise. That's why conduit runs usually terminate above the ground, not below. The trick is to find the conduit end without blowing off the seal. Hi Jeff It may be of little interest to the OP, but the sand might have difficulty leaking back into a conduit with air blowing out of it. In addition, the air might leak from a small rupture below the oipen end of the conduit. The OP may have no access to compressed air anyway. Jerry KD6JDJ Welcome to rec.radio.amateur.antenna.physics Ok, let's do the math. Dry sand weighs 100 lb/cubic-foot. There's about 1 ft of sand above the end of the 3/4" conduit. The weight action is roughly conical, so the volume of sand involved is (my guess) about: 100 lbs/ft^3 * 1/3 = 33 lbs of sand. All that it acting on a 3/4" diameter pipe, with a cross sectional area of about: Pi * 0.75" = 2.4 in^2 Therefore, the pressure exerted by the sand is: 33 lbs / 2.4 in^2 = 14 PSI So, if he can pressurize the pipe to more than 14 PSI, he can lift the column of sand sufficiently to keep it from dribbling into the pipe. Of course, it's not that simple. Laminar air flow, pressure gradients across the conduit, and the effects of the duct tape will ruin my simplistic guesswork. Worse, the back pressure created by the immovable column of sand will force some sand particles into the conduit around the edges with the "reflected" air pressure. In the middle of the conduit, the air flow is all out of the conduit, but near the edges, it could easily be the other direction. I'm also assuming that the sand is a perfect air seal, which it's not. To prevent all this from happening, the minimum air pressure should be about twice the 14 PSI, which is easily achievable with an air compressor, but not a vacuum cleaner. I'm also trying to imagine how the process will work. I see an air compressor pumping madly away as the neighbors kids furiously dig around the resultant sand volcano, as sand rapidly refills the conical hole. In my never humble opinion, there's no way to prevent sand from dropping into the conduit if the duct tape seal is broken before excavating the end of the conduit. Once the sand is in the conduit, just blowing air through the pipe isn't going to magically elevate the sand particles 1ft or more in the air. The air does not have sufficient mass to convey enough momentum to move the sand particles, much less eject them vertically. For that, one needs a denser medium, such as water. Shoving a plunger through might work, but it's equally likely to jam sand particles into the PVC conduit walls. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Forum | |||
| Locating the source of a number station | Shortwave | |||
| Antenna cables in metallic conduit? | Antenna | |||
| Underground Bases | Shortwave | |||
| Pulling Cable in Conduit | Antenna | |||
| Underground antennas | Shortwave | |||