Home |
Search |
Today's Posts |
|
#1
![]() |
|||
|
|||
![]() On Nov 28, 12:51*pm, Richard Clark where the question remains at: where did you get ...72 mV/m from? It is evident your field quote is NOT from this specific Mininec r-f ground model of yours above. Can you not view the screen clip at the link I posted showing this? Why do you keep asking? All of the windows shown in my screen clip resulted from the NEC model data appearing in the upper left window of that clip, and all windows in the clip appeared on the screen at same time and were driven by that data. Note the selection of a Real/MININEC ground in the EZNEC window in the upper left corner, and the further selection of a "medium ground" on the line below. One of the other windows there shows the "near-field" value of 72 mV/m at 1 km for 1 kW of radiated power for this model. Are you comprehending all that is shown in that clip? More interesting would be his enquiry or explanation into how you defeated the lock-out for a feature that is a poor method for near field analysis. No defeat of such was necessary. EZNEC produced the data results for my model exactly as shown in my screen clip, with no complaints or subterfuge on my part. RF |
#2
![]() |
|||
|
|||
![]()
On Fri, 28 Nov 2008 12:07:05 -0800 (PST), Richard Fry
wrote: On Nov 28, 12:51*pm, Richard Clark where the question remains at: where did you get ...72 mV/m from? It is evident your field quote is NOT from this specific Mininec r-f ground model of yours above. Can you not view the screen clip at the link I posted showing this? Why do you keep asking? Because in a commercial release, suitable to professional and scholarly reporting, it is obviously locked out as an available option - by design and documented as so. A screen shot does not describe your actions. You need only explicitly state that when you selected the mini-nec ground model, that you had the NF button available and you selected it. If such is the case, it is a bug in Roy's demo - caveat emptor. I don't do research with demo applications. The long and short of it is that what your poor model reveals is a departure from the data found in the BL&E paper "Ground Systems as a Factor in Antenna Efficiency." You 1. do not have a construction of radials of any type; 2. do not have a radiator sized to their specification; 3. employ an engine (mini-nec) which is poorly suited to the task; 4. excite the model at a frequency not supported in data in BL&E; 5. fail to note the documented advisories about near field operation below 3MHz when such analysis is available. There is no point in asking for how to "fix it" when your model is irreconcilably crippled. Using a demo version of EZNEC is not suited to the task. You couldn't even use my model as it is constructed with fine granularity that exceeds the capacity of EZNEC, and supported only with EZNEC+. There are alternatives that are free, and unlimited in their segment counts available which is necessary for a proper analysis. Caveat emptor still prevails, and you get the quality of support you pay for. I would "suggest" given all the cautions, contrarian advisories offered, and warnings direct from the tool's author, that their cumulative effect would seem to doom you to disappointment if you demand something better than several percent concurrence to the data supplied in the BL&E paper "Ground Systems as a Factor in Antenna Efficiency" when abstracted to other applications. 73's Richard Clark, KB7QHC |
#3
![]() |
|||
|
|||
![]() On Nov 28, 3:24*pm, Richard Clark posted: Can you not view the screen clip at the link I posted showing this? Why do you keep asking? Because in a commercial release, suitable to professional and scholarly reporting, it is obviously locked out as an available option - by design and documented as so. A screen shot does not describe your actions. *You need only explicitly state that when you selected the mini-nec ground model, that you had the NF button available and you selected it. * To humor you, then... I explicitly state that when I selected the Real/ MININEC ground model, I had the NF button available and that I selected it. The result of that analysis is included in the screen clip at the link I posted, and which you seem unable to comprehend. Also please note that I have already described and documented my EZNEC model and actions in far more detail than you have done for yours, so far. Note further that the Demo versions of EZNEC operate exactly the same as the paid versions, except for the number of segments permitted in the model -- which was not a factor in the model I constructed. I'm sure that Roy or someone else will correct me if that statement is provably wrong. The long and short of it is that what your poor model reveals is a departure from the data found in *the BL&E paper *"Ground Systems as a Factor in Antenna Efficiency." *You 1. *do not have a construction of radials of any type; Their effect was included as I described in an earlier post. I will understand if this concept evades you. 2. *do not have a radiator sized to their specification; A 1/4-wave monopole is a 1/4-wave monopole, regardless of the operating frequency. The intrinsic radiation envelope for a given radiated power actually launched by such a monopole (e.g., apart from the effects of the propagation environment) is the same at all those frequencies. If not, the FCC would/could not have adopted the results of the BL&E experiments at 3 MHz as applicable to the entire MW AM broadcast band (which they did). 3. *employ an engine (mini-nec) which is poorly suited to the task; A MININEC ground itself is not an engine. It is a only a condition used by the NEC engine. 4. *excite the model at a frequency not supported in data in BL&E; See my response to your 2 above. In reality, surface-wave ground losses in the MW BC band are less than at the 3 MHz freq used in the BL&E studies, so the applicability of their findings is even more relevant to BC operations. 5. *fail to note the documented advisories about near field operation below 3MHz when such analysis is available. No such advisory was presented by/in EZNEC during the process of generating and analyzing my model. I suggest you cool it for a while, and wait to see what Roy Lewallen might post about all of this. RF |
#4
![]() |
|||
|
|||
![]()
It's possible to run a near field analysis using MININEC type ground
with some v. 4.0 and all v. 3.0 and earlier versions of EZNEC. However, the results will be wrong. The problem with using near field analysis and MININEC type ground was discovered while v. 4.0.27 was current, and the restriction preventing that combination was introduced at v. 4.0.28 in August 2006. So only v. 4.0.28 and later programs have this restriction. Please see the last paragraph of this posting for remedies. In EZNEC v. 4.0.28 and later, the NF Tab button is greyed out whenever a MININEC-type ground is specified. If it's clicked, you'll see a message that near field analysis is disabled when MININEC-type ground is specified. If you click Help in the message window, it'll open the manual topic which discusses real ground types. There, you'll find: --------------- Near field analysis is disabled when MININEC-type ground is selected. Tests have shown that, because of the fundamental way NEC does calculations, near field analysis with MININEC-type ground can produce significantly erroneous results, particularly in the vicinity of a wire which is connected to ground. This is really a contrived situation anyway, because the only way to achieve a ground connection for a real antenna comparable to the MININEC-type ground model is to install a radial system. This will alter the ground conductivity and local fields, so the MININEC-type ground model isn't really representative of conditions near a grounded wire in any case. Use some other ground type for near field analysis. --------------- If the conclusion that EZNEC near field results differ from the FCC ground wave predictions is based on a near field analysis with MININEC-type ground, I'm not surprised at the disagreement. The analysis should be redone with a large number of radials just above the ground, and High Accuracy ground used instead of MININEC-type ground. Two reminders: 1. As explained in the EZNEC manual, "near field" analysis isn't restricted to the near field. It's actually "total field" -- including ground wave -- and is accurate at any reasonable distance. The "near field" nomenclature is carried over from NEC. 2. The EZNEC ground model is flat and infinite in extent. So the predicted direct line field begins deviating from actual field values where the curvature of the Earth becomes a significant factor. Anyone using EZNEC v. 3.0 and earlier should avoid using the combination of near field analysis and MININEC-type ground. Anyone using v. 4.0 should update his program to the last revision of that version, 4.0.39. You can find instructions on updating in the manual, Support/Updates (Maintenance Releases). To determine which revision you have, click Help in the main program window, then About EZNEC. I strongly recommend that v. 5.0 users periodically check for updates. Roy Lewallen, W7EL |
#5
![]() |
|||
|
|||
![]()
On Fri, 28 Nov 2008 15:39:35 -0800 (PST), Richard Fry
wrote: wait to see what Roy Lewallen might post about all of this. Are you going to ask for a refund? 73's Richard Clark, KB7QHC |
#6
![]() |
|||
|
|||
![]()
Richard Fry wrote:
. . . Note further that the Demo versions of EZNEC operate exactly the same as the paid versions, except for the number of segments permitted in the model -- which was not a factor in the model I constructed. I'm sure that Roy or someone else will correct me if that statement is provably wrong. . . . You are correct. The demo is exactly the same as the standard EZNEC program except for the segment limitation. But I recommend using the current demo program rather than an older version or revision. Demo programs can be updated at any time by downloading and installing the current demo from http://eznec.com/demoinfo.htm. The old program can be uninstalled first if desired; otherwise the new one will overwrite the old one. This process won't harm any saved description files. Roy Lewallen, W7EL |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Elevation Patterns of Ground Mounted Vertical Monopoles | Antenna | |||
FS: Hy-Gain AV-640 Vertical (Mint) | Swap | |||
Vertical ant gain vs No radials | Antenna | |||
FS: Hy-Gain AV-640 Vertical (Mint) | Swap | |||
1/4 wave vertical vs. loaded vertical | Antenna |