Home |
Search |
Today's Posts |
#8
![]() |
|||
|
|||
![]()
"Dave Platt" wrote in message
... In article , Jeff Liebermann wrote: Beware of the Aluminum foil and shields though. Once it gets wet there is no stopping the internal corrosion and will generate broadband noise under power. This includes both RG6 and 9913 and LMR types. They have been banned from all commercial sites around here. Amazing. I can see it's possible to create a diode mixer junction with electrolytic action between the aluminum foil and copper braid. I've never seen broadband noise from coax cable. Usually the foil is mylar or polyester coated and the copper is tinned or silver plated to eliminate any points of contact. Most of the radio sites I've seen are stuffed LMR-400 and LMR-600. Heliax is better, but also far more expensive. Incidentally, if you want to generate RF noise and mixing, there's nothing better than an abraided Heliax outer jacket, with the copper shield touching the zinc galvanized tower. If intermod were really a problem with foil shielded coax, then the common residential CATV distribution system would have a big problem with intermod and mixes. While the buried coax is semi-rigid with a solid aluminum shield, the pole to house drops are usually quad shielded RG-6/u (sometimes with a messenger wire) with foil and braid shields. I don't think those cases (commercial/repeater and CATV) are comparable. As I understand it (anecdotal report and discussions with other repeater owners/builders), the problem with LMR-400 and similar cables occurs when the cable is used in a duplex application, with RF transmit power and the incoming receive signal being carried on the same cable simultaneously. Under these conditions, it doesn't take very much broadband noise generation at all (from the cable, connectors, or nearby metal-on-metal contacts) to cause a problem. The transmitter might be pumping 50 volts RMS of power into the cable, while the receiver is trying to pick off a signal of less than a microvolt at a frequency only 600 kHz away. That's a rather critical environment which really can't tolerate more than a tiny percentage of noise generation in the cables, connectors, or duplexer. I don't think there's any problem with using these sorts of cables in commercial or amateur service in *simplex* applications... they can handle transmitting, or receiving, just fine. It's only when you try to do both, simultaneously, through the same cable. that the noise generation can become a problem. The same can be true of some classes of antenna problems. The repeater system I help maintain developed a serious desensitization problem, due to internal corrosion/oxidation which occurred in the antenna after several years up in the weather. I doubt that the corrosion/oxidation effect would ever have been noticed if the antenna were in service as a normal (simplex) base antenna - it didn't affect the transmit SWR or the receive sensitivity at all, I believe that CATV distribution is a rather easier situation for the cable to handle, since the signals being carried are all of a fairly similar and moderate power level. The downstream carrier levels delivered to the home seem to be around 1 millivolt... that's more than 60 dB higher than what a repeater's receiver has to be able to pick out when it's receiving a just-usable signal from the outer edge of its service area. You got it. Only hardline is authorized on the tower. Hardline doesn't have the problem because it doesn't have a braid to flex in the wind. Braid is less than satisfactory for RF Ground and lightning protection too. Copper ribbons and sheets are preferred for grounds, but regular large copper cable can be substituted in some cases. On a repeater system, corroded or old braided coax hoses your own receiver and others nearby on the tower or the next building with noise. Especially in the wind. You won't hear that on simplex because the receiver is muted when you transmit. I don't know if you have seen CATV hardline with a tank strapped to the utility pole. That keeps water out by pressurizing the hardline. CATV systems DO have problems with corrosion all the time. With all that cable though, the cost to get it up and running is enormous, and they would rather be complaint driven instead. They also use circulators so that the stuff people do in their house doesn't feed back into the system and screw all the other customers up. The 2m people, most business PLMR and the Cops don't get it so they complain about jammers so you get irate service calls. But you can't talk to them because if you talk technical, they cover their ears, scream LALA LALA!! accuse you of lying, and they won't pay for the cure anyway (remember, if you have to think about the answer, you're lying). We do use LMR and 9913 for cheap simplex ground level base station installs because it is cheaper and easier to route. Don't use it around your rotor though. The foil will tear up. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Group Velocity and Velocity Factor | Antenna | |||
Velocity factor | Antenna | |||
velocity factor??? | Antenna | |||
Stripped off coax velocity factor | Antenna | |||
Measuring Velocity Factor w/ MFJ-259 | Equipment |