The possibility of common-mode current on the outside of the braid has
been mentioned, but nothing has been mentioned concerning whether a balun is used if the feedline-antenna connections is unbal to bal. If there is no balun where should be one, seems to me it's a no-brainer that the problem is common-mode current causing the different SWR readings with different lengths of feedline. Walt, W2DU Hi Walt, I have always used a good balun on all my antennas, and therefore I am not too convinced that, in my case, the SWR change I observe when adding (or removing) a piece of coax in my station could be due to RF presence on the coax braid. Anyway, I have not yet read a clear and convincing explanation of why the presence of RF on the coax braid would cause the SWR meter to give a different reading when moving it along the line. I appreciate that, with a hot braid, the coax cable becomes part of the antenna and then radiates, but I cannot clearly focus why this can cause the SWR meter to see different impedances at different points of the line. Impedance is the ratio between RF voltage (between center conductor and braid) and (differential mode) RF current. So, I do not well visualize how the presence of a common mode RF current can influence the meter reading. 73 Tony I0JX |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Group Delay Variation - How much is too much? | Homebrew | |||
variation of number station | Shortwave | |||
interesting variation in the DA5 | Shortwave | |||
Variation in modeling predictions between software | Antenna |