Home |
Search |
Today's Posts |
#11
![]() |
|||
|
|||
![]() "Owen Duffy" wrote in message ... "Peter" wrote in . au: ... I must admit I had assumed that the 269 analyzer display the sign of the reactance, I will have to reread the ad. Ah, you were looking for honesty in advertising! The online guff on the MFJ259B says: "Read Complex Impedance as series resistance and reactance (R+jX) or as magnitude (Z) and phase (degrees)." The MFJ259B definitely does *not* show phase angle or reactance as negative for cases where X is actually negative. The same words appear in the MFJ269 online page, so it may also be a misrepresentation. I see in the MFJ269 manual, the same pretence over the sign of phase and reactance. It contains the words "Besides Z, an angle between zero and 90 degrees is shown. This angle represents the phase difference between current and voltage at the terminals of the analyzer." Of course, a phase angle between "zero and 90 degrees" does not represent "phase difference between current and voltage at the terminals of the analyzer" in the case of a capacitive impedance. Honesty in advertising... think again. Owen What was I thinking! I was impressed with what was being claimed. I will continue with my product research and you can expect me to float some other manufactures device on this group soon for comments. Peter VK6YSF http://members.optushome.com.au/vk6ysf/vk6ysf/main.htm |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
antenna analyzer | Swap | |||
FS MFJ 259 Antenna Analyzer | Swap | |||
Antenna analyzer? | Antenna | |||
FS: MFJ-249 Antenna Analyzer | Swap | |||
WTB: Antenna Analyzer | Swap |