Jeff wrote:
So if what you are saying is correct then terminating a piece of coax with a 50 ohm resistor will not cause a perfect match and the load will not be 50 ohms due to the shunt impedance to earth of the coax braid. I think not. Maybe you can draw a diagram and show yourself where the current flows. The earth connection on the shield outside is in parallel with the earth connection on the shield inside. You can't have any current flow on the outside because any current flowing on the shield inside balances with the current flowing in the center conductor. The resistor requires the two currents are equal with none left to travel down the shield outside. Indeed, as you state there is no current flow on the outer of the coax; the same situation exists for a perfectly balanced dipole attached directly to the coax, as far as the coax is concerned the situation is no different, all it sees is a perfectly matched load, just like the resistor, all of the power is dissipated in the antenna and none flows anywhere else including the coax outer. Jeff That current flows on the outside of the shield is observable and measurable. How much flows is totally dependant on how long the shield is and whether or not it is grounded somewhere along the way. -- Jim Pennino |