On Sat, 1 Jan 2005 14:06:25 -0600, "H. Adam Stevens, NQ5H"
wrote: Richard The tower's a 48' Trylon self-supporting affair. The base, rebar cage, and additional rebar driven into the hole walls for positioning are all welded together. The contractor made damn sure the base will remain plumb during the pour. I intend to use 3 - 6 additional rods outside the cage attached to the legs with big cable. Not familiar with the term "Ufer"? 73 H. Hi OM, Concrete is conductive and with the large surface area presents quite an electrode - the Ufer ground. Providing for a connection to its metal interior insures you have access to this characteristic (and with the rebar welded, insures that there will be no exploding concrete at the J-Bolts due to current crowding if/when lightning strikes). 73's Richard Clark, KB7QHC |