I use a single point grounding system. There is a ground rod driven
at the service entrance to which electrical, telephone, and one of two satellite systems are connected. I have run #2 copper from that location to a total of 14 other ground rods each one 5/8" x 8', driven completely in the earth and spaced at least 10' from each other. My 70' guyed tower is about 80' from this location and connected to the grounding system. Each guy wire is also grounded. The aluminum plate where all antennae enter the building on the second floor is connected to this grounding system with #4 copper (to be replaced this summer with 4" flat copper ribbon). Inside the building, there is a bus bar which is connected to the flat aluminum plate where the antennae enter. All the feedthroughs use gas plug protectors. All coaxial feedlines are formed into a coil before being connected to the pass-through plate. My question: Some radio equipment are also grounded by three prong plugs. Doesn't that constitute a ground loop? I've never gotten a satisfactory answer to this question. Thanks, -- Larry W1HJF Email to rapp at lmr dot com |