John Smith wrote:
http://blake.prohosting.com/mailguy2/swr1.jpg http://blake.prohosting.com/mailguy2/swr2.jpg This should prove as "proof of concept" that an "indicator" using such a toroid should darn well work! ... at the very least--in the fashion I am attempting... If you will notice, your earlier versions did not sample the voltage. These designs sample the voltage through C1 and C2. The current is sampled by T1. The voltages are phasor-added to the current to obtain signals proportional to forward power and reflected power. Those voltage sampling caps are what were missing from your earlier designs. -- 73, Cecil, http://www.qsl.net/w5dxp ----== Posted via Newsfeeds.Com - Unlimited-Uncensored-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |