Now, now, gentlemen, there's no need to re-start the Civil War. Put
away your literary weapons. The slaves have all been freed and we now have computers. A 100 turn coil, 10 inches long, 2 inches in diameter, has an inductance of 102 microhenrys, a Q of aproximately 380 at F = 1.9 MHz, and the self-resonant frequency is 12.0 MHz. Its radiation resistance at 1.9 MHz is negligible. It is near enough to being exactly 100 microhenrys to justify it being called an Inductance Standard. ---- Reg. |