Home |
Search |
Today's Posts |
|
#1
![]() |
|||
|
|||
![]()
Buck wrote:
I gathered that from an earlier post, but I think the confusion comes in the second second, doesn't it? 100 watts of power is generated from the generator for two seconds. the first second, 100 watts travels to the antenna and only 100 watts is in the transmission line. Then for the second second, 100 forward watts is moving towards the antenna and 50 reflected watts are returning to the transmitter for a total of 150 watts in the transmission line? Of course, since the transmitter isn't matched to the antenna, the reflected power is reflected again for 25 watts being reflected back to the antenna bringing the power from 100 forward watts to 125 watts (the reason power meters go up in wattage when SWR rises) thus the antenna reflects 62.5 watts which adds to the 125 for a total of 187.5 watts in the transmission line. Sooner or later one will have a meltdown that will make Chernoble look like a firecracker compared to a fireworks display. lol Actually, the forward power levels off at 200 watts during steady- state. The reflected power levels off at 100 watts. 300 joules of energy exist that have been sourced but not dissipated in the load. 300 joules are exactly what the forward wave and reflected wave need to support their existence. Here's the brainteaser configuration: 100W-SGAT---one second long lossless 50 ohm feedline---291.42 ohm load The 'SGAT' is a signal generator equipped with a super fast auto-tuner that re-reflects all the reflected power back toward the load so there are no losses at the source end. The only losses in the entire system are in the 291.42 ohm load which, to make the math easier, was chosen for a power reflection coefficient of 0.5, i.e. half the incident power is reflected at the load. I will generate an EXCEL spreadsheet today that will give a second by second summary of the powers and total energy. In the meantime, here is a more simplified version of the brainteaser. 100W-SGCL---one second long lossless 50 ohm feedline---291.42 ohm load The 'SGCL' is a signal generator equipped with a circulator and 50 ohm resistor. During steady-state, half the generated power is dissipated in the load and half in the circulator resistor. There are no re- reflections at the source. During the 1st second, the source supplies 100 joules into the feedline. There is no dissipation either in the load or circulator resistor. During the 2nd second, the source supplies another 100 joules into the feedline, 50 joules of which are converted to heat in the load and 50 joules of which are reflected from the load as 50 watts of reflected power. At the end of the 2nd second, the feedline contains 150 joules of energy. During the 3rd second, steady-state is reached. Of the 100 watts sourced, 50 watts are dissipated in the load and 50 watts are dissipated in the circulator resistor. At the end of the 3rd second, the source has generated 300 joules, 100 of which have made it to the load, and 50 of which have made it to the circulator resistor. 300-100-50 = 150 joules stored in the feedline. 100 joules are stored in the 100W forward wave. 100 joules/sec = 100W 50 joules are stored in the 50W reflected wave. 50 joules/sec = 50W This conservation of energy works for any length feedline. If the feedline were one microsecond long instead of one second long, there would be 150 microjoules stored in the feedline, 100 microjoules in the forward wave and 50 microjoules in the reflected wave. -- 73, Cecil http://www.qsl.net/w5dxp |
#2
![]() |
|||
|
|||
![]()
On Fri, 26 May 2006 12:41:45 GMT, Cecil Moore
wrote: Buck wrote: All this technical detail is interesting, but in the last thirty years of hamming, I have taken note to know the following: My radio is most happy when matched with an SWR of less than 1.8:1 If my antenna exceeds that, either adjust it or use a tuner The higher I raise my antenna, the better. A yagi works better than a dipole given the same height and direction. A dipole works better to the west than a beam pointed north. i would rather have a high gain antenna than a high power amp. Most importantly: If band conditions permit, I can talk across the ocean on an antenna with a 30 db loss, but with certain band conditions, even a 30 db gain antenna won't make the contact! I can't tell you how many joules are in my coax, but, if you ask, I can tell you how many jewels are in my logbook. ![]() -- 73 for now Buck N4PGW |
#3
![]() |
|||
|
|||
![]()
"Buck" wrote:
I can't tell you how many joules are in my coax, but, if you ask, I can tell you how many jewels are in my logbook. ![]() This is not aimed at people who don't care about such things. This is aimed at people who do care about such things especially those who are disseminating false technical information about such things. Some say that since there's 100 watts in and 100 watts out during steady-state, there's nothing left over for the reflected waves. They apparently forgot about the time immediately following power up when there was 100 watts in and less than 100 watts out. -- 73, Cecil, W5DXP |
#4
![]() |
|||
|
|||
![]()
I've lost the original question.
But there is a lossless transmission line 1 second long. With a velocity factor of 1.0 it is 30,000 kilometres long. Let Zo = 100 ohms. Let applied volts = 100 VDC. Let terminating resistance be 100 ohms. Line Inductance = 10,000 Henrys. Line Capacitance = 1 Farad. Under steady state conditions - Line current = 1 amp. Energy stored in inductance = Sqr(I)*L/2 = 5000 Joules. Volts across capacitance = 100 volts. Energy stored in capacitance = SqrV)*C/2 = 5000 Joules. Total energy stored = 10, 000 Joules = 10,000 watt.seconds. Which has nothing whatsoever to do with all this nonsense about reflections. Note that energy in inductance equals energy in capacitance. (I trust I have not made a mistake with the arithmetic.) ---- Reg. "Cecil Moore" wrote in message . net... "Buck" wrote: I can't tell you how many joules are in my coax, but, if you ask, I can tell you how many jewels are in my logbook. ![]() This is not aimed at people who don't care about such things. This is aimed at people who do care about such things especially those who are disseminating false technical information about such things. Some say that since there's 100 watts in and 100 watts out during steady-state, there's nothing left over for the reflected waves. They apparently forgot about the time immediately following power up when there was 100 watts in and less than 100 watts out. -- 73, Cecil, W5DXP |
#5
![]() |
|||
|
|||
![]()
Reg Edwards wrote:
Let Zo = 100 ohms. For what range of frequencies is the above true? -- 73, Cecil http://www.qsl.net/w5dxp |
#6
![]() |
|||
|
|||
![]() For what range of frequencies is the above true? -- 73, Cecil http://www.qsl.net/w5dxp ==================================== If you ask silly questions you can expect silly answers. Are you looking for a reason to introduce your irrelevant reflections again. --- Reg. |
#7
![]() |
|||
|
|||
![]()
Reg Edwards wrote:
If you ask silly questions you can expect silly answers. Are you looking for a reason to introduce your irrelevant reflections again. No, just trying to correlate your example to mine. In your example, how long does it take from power up for the load to accept 100 joules/second? -- 73, Cecil http://www.qsl.net/w5dxp |
#8
![]() |
|||
|
|||
![]()
Reg Edwards wrote:
I've lost the original question. But there is a lossless transmission line 1 second long. With a velocity factor of 1.0 it is 30,000 kilometres long. Let Zo = 100 ohms. Let applied volts = 100 VDC. Let terminating resistance be 100 ohms. Line Inductance = 10,000 Henrys. Line Capacitance = 1 Farad. Under steady state conditions - Line current = 1 amp. Energy stored in inductance = Sqr(I)*L/2 = 5000 Joules. Volts across capacitance = 100 volts. Energy stored in capacitance = SqrV)*C/2 = 5000 Joules. Total energy stored = 10, 000 Joules = 10,000 watt.seconds. Which has nothing whatsoever to do with all this nonsense about reflections. Note that energy in inductance equals energy in capacitance. Yep, you don't have to mess with those pesky reflections when the line is terminated in a load equal to its characteristic impedance. Then the problem reduces to the trivial one you've posed. Simple problem, simple solution. Roy Lewallen, W7EL |
#9
![]() |
|||
|
|||
![]() "Roy Lewallen" wrote Yep, you don't have to mess with those pesky reflections when the line is terminated in a load equal to its characteristic impedance. Then the problem reduces to the trivial one you've posed. Simple problem, simple solution. ======================================= As I say, I've lost the original question. But if a steady-state answer is needed for the original question then the answer can be found by the same simple means without the unnecessary complication of reflections. It's the Devil which makes Cecil pose such loaded questions. ---- Reg. |
#10
![]() |
|||
|
|||
![]()
Reg Edwards wrote:
It's the Devil which makes Cecil pose such loaded questions. It's only loaded with the conservation of energy principle, Reg. Here's a simple example. The SG-CR is a 50 ohm signal generator equipped with a circulator resistor to dissipate all reflected power incident upon the source. 200W SG-CR---one second long lossless 50 ohm line---291.42 ohm SWR is 5.83:1 rho^2 = 0.5 Steady-state forward power is 200 watts. Steady-state reflected power is 100 watts. The question is: After steady-state has been reached, how many joules of energy have been generated but have not been dissipated in the load resistor or circulator resistor? -- 73, Cecil http://www.qsl.net/w5dxp |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
brainteaser exercise | Antenna |