Home |
Search |
Today's Posts |
|
#1
![]() |
|||
|
|||
![]()
Scott Dorsey wrote:
Could be, stick it on a bridge and see. Is it leaking? Not physically ![]() It may not have a 115vac regulated output. Some of the Sola transformers were step-up or step-down. A call to Sola should identify the part number. I have seen some with 24VAC secondaries. I tried calling them but the guy basically laughed and told me good luck. My understanding is its the Sola name but owned by a different company. I tried searching to see if anyone had scans of an old catalog but no luck. Is the thing rated for 60cycle use? A 50 cycle ferroresonant transformer will go berserk on 60 cycle power. --scott Its definitely 60 cycle. The supply runs a "super pressure" mercury arc lamp for an optical comparator. Up until yesterday its had regular use for years but now the lamp will not sustain an arc. The only problem that stands out is seeing 60 volts on the caps rated for 150. Thanks for the quick reply. Adam |
#2
![]() |
|||
|
|||
![]()
Adam Stouffer wrote:
Its definitely 60 cycle. The supply runs a "super pressure" mercury arc lamp for an optical comparator. Up until yesterday its had regular use for years but now the lamp will not sustain an arc. The only problem that stands out is seeing 60 volts on the caps rated for 150. Thanks for the quick reply. Get the data sheet for the arc lamp itself and see what voltages it is supposed to have for starting and running. Then work back from there. If I saw a low voltage on the supply filter caps I would check the rectifiers before anything else. --scott -- "C'est un Nagra. C'est suisse, et tres, tres precis." |
#3
![]() |
|||
|
|||
![]() |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Ireland - Solas AM call it a day | Broadcasting |