| Home |
| Search |
| Today's Posts |
|
#3
|
|||
|
|||
|
It is an EC2002A from way back. A nice clean unit except for the display
problem. I dug into it this weekend hoping it was just a bad capacitor in the PS. It did start to work for a short time. There are numerous potentiometers in the thing, its possible one is intermittent. w9gb wrote: "**THE-RFI-EMI-GUY**" wrote in message . .. Subject: Intersil CA3162E/CA3161E A/D BCD/7Segment problem Weller Soldering Station Hi I am trying to fil my Weller soldering station which has lost its temperature readout. This particular model has the Intersil CA3162E/CA3161E A/D and BCD/7Segment chips. When first turned on the display flashes "EEE" and then goes blank. I shotgunned the repair by replacing the filter caps in the power supply and though I had it fixed but it is back to same problem. In reading the Intersil application notes for the A/D convertor I don't see a logical mode where EEE would be displayed Does anyone have advice for troubleshooting this configuration? -- Joe Leikhim K4SAT "The RFI-EMI-GUY"© Joe - Which model are you trying to repair? EC 2002M ? Positive your handpiece is okay? (Type-K thermocouple can go bad) Bob Wurth just happens to have replacement control board on eBay -- item number: 270057328135 reasonable price Greg -- Joe Leikhim K4SAT "The RFI-EMI-GUY"© "Treason doth never prosper: what's the reason? For if it prosper, none dare call it treason." "Follow The Money" ;-P |