Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old August 26th 10, 03:22 AM posted to rec.radio.amateur.homebrew,sci.electronics.design
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 349
Default Heating in 4-1/2 turn inductor


"amdx" wrote in message
...

"Jeff Johnson" wrote in message
...


"amdx" wrote in message
...

"Jeff Johnson" wrote in message
...


"amdx" wrote in message
...
Several years ago while making inductors for tuning a class E
amplifier we
end up with a 4-1/2 turn inductor. The inductor used a 3F3 potcore,
gapped I think,
but it has been awhile. The inductor was driven hard but below
saturation.
The problem; the 1/2 turn got HOT. Four turns or five turns were ok.
My physicist friend had an EE verify the problem 2000 miles away.

So, can anyone tell me why 1/2 turn would make such a difference in
the heating?

Thanks, MikeK



Resonance? (I assume by 1/2 you mean the 4.5 inductor?)
Yes, a 4 and 1/2 turn inductor had the 1/2 turn overheat.


huh?

The half turn and the other turns were ok? This is impossible!?!?!


Not impossible, there's more than one heating mechanism, not that I can
explain them,
but I know there can be heating in the fringe field of the gap.

One has the same current through the whole coil and if the wire was
uniform then it should heat heally well. Not only that copper is a good
heat conductor so if the 1/2 turn was heating up then he heat should
spread pretty quickly.

This assumes everything else is uniform along the coil. Something has to
be going on that your not telling us? Ideally the heat should be
uniformly distributed along the coil.

By "HOT" I assume you mean much much hotter than the other coils?


Hot enough to burn the insulators used.

Heat is generated by the current, is it not? and the current should be
uniform throughout the wire? The resistance of the wire itself should
also be uniform. This suggests that the heat dissipated per unit length
is independent of position.


Flux my not have been uniform through.

Were both ends hot? If not then something else is going on. Because you
are saying the .5 end of a 4.5 coil got HOT. Yet which end? the 4.5 coil
has two .5 ends and should in theory be symmetric and hence both get
equally HOT. If they wern't then something is aloof.

LOLROTF, ya both ends would be a 1/2 turn??? I'm speechless
and don't know what to say. :-) Don't confuse me with such things!
MikeK

BTW we were use the inductor at about 660 khz.
Mike


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Drake R8 POP..On turn on Justis Shortwave 16 June 28th 08 10:38 PM
heating padRFI? Amerigo Vespucci Antenna 6 August 12th 06 10:12 PM
Self-heating of crystal in inverter oscillator Ben Jackson Homebrew 10 July 5th 06 02:28 AM
Drayton Lifestyle LP241 central heating control. Alasdair Digital 0 May 19th 06 07:54 PM
Turn $5.00 into 15,000 in 30 days wfbathome Shortwave 0 May 23rd 05 09:34 PM


All times are GMT +1. The time now is 06:59 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017