"raypsi" wrote in message ... Hey OM: First how many newsgroups do you have this thread cross posted on? How many do you see it on? Second: A 1/2 turn is equal to 1 turn in a pot core so 4 and 1/2 turns is the same as 5 turns. I don't think so. If I put 4-1/2 turns on a potcore and measure inductance, then unwind the 1/2 turn, do you think the inductance will measure the same? Lastly OM: I think you are looking at a classic case of proximity effect. It may be, but I can't explain to myself how that would happen. I do think it has something to do with the flux through the coil though. Thanks, MikeK 73 OM de n8zu On Aug 25, 4:09 pm, "amdx" wrote: Several years ago while making inductors for tuning a class E amplifier we end up with a 4-1/2 turn inductor. The inductor used a 3F3 potcore, gapped I think, but it has been awhile. The inductor was driven hard but below saturation. The problem; the 1/2 turn got HOT. Four turns or five turns were ok. My physicist friend had an EE verify the problem 2000 miles away. So, can anyone tell me why 1/2 turn would make such a difference in the heating? Thanks, MikeK |