Home |
Search |
Today's Posts |
#9
![]() |
|||
|
|||
![]()
I have never experienced that
crowbar has been a need for the power supplies It's in large part an economic decision - why protect something if it doesn't have much value? In many cases not having a crowbar means not really needing regulation. Is your desire for regulation mainly to get rid of hum? I intend to use toroid transformer, and believe the output voltage varies somewhat more than for a standard E-core transformer I've had good luck buying medium duty (several hundred VA rated) toroid transformers on E-bay and rewinding them for my own uses. You'll need something like 1000 VA, and I think these exist but haven't paid much attention. It's generally easier for me to add/replace windings to toroid transformers than to unshellac a E-core transformer and rewind. Some toroids have shellac type coatings but many of the big ones are just kinda plastic-wrapped (not exactly heat shrink because heat shrink doesn't come in toroidal forms!), which makes things really easy. Tim. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
HELP Astron 70 amp PS | Boatanchors | |||
Wanted: Power Supply for TR-4C | Equipment | |||
Wanted: Power Supply for TR-4C | Equipment | |||
FS: Astron RS-70M (70 Amp) Power Supply | Swap | |||
Derivation of the Reflection Coefficient? | Antenna |