In class G or H amplifiers you do vary the supply voltage. But not much
out there on class G or H amps. I'm suprized nobody mentioned class G
or H.

I have two 4x150G's These are 1000 VDC plates, and coax style
connections. I'm running:
at 144mhz
800VDC on the plates dual input choke supply
375 on the screens regulated and protected
-50 on the grids, adjustable for any class, regulated and protected
grounded cathodes
Push pull
With a strip line low pass filter for 2M on the output -60db

73
Ray KC8OJU

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
How many licenses should there be, why and what privileges? Bill Sohl Policy 113 January 8th 06 09:42 PM
Constant bandwidth TRF circuit John Byrns Shortwave 6 June 14th 04 01:55 AM
New ARRL Proposal N2EY Policy 331 March 4th 04 12:02 AM
Why You Don't Like The ARRL Louis C. LeVine Policy 803 January 23rd 04 01:12 AM
RF amps: tuned load in Class A? Don Pearce Homebrew 141 September 15th 03 05:02 AM


All times are GMT +1. The time now is 09:38 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017