Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old September 29th 08, 10:11 PM posted to rec.radio.amateur.moderated
external usenet poster
 
First recorded activity by RadioBanter: Mar 2008
Posts: 115
Default How do I check if old coax is still usable?

I have a run of RG-8 coax inside a conduit, and I'd like to keep it in
service if possible. How can I test it before I risk my finals trying to
put power into it?

It's OK AFAICT with a VOM.

73, Bill W1AC
--
Bill Horne

(Remove QRM from my address for direct replies.)

  #2   Report Post  
Old September 30th 08, 01:51 AM posted to rec.radio.amateur.moderated
external usenet poster
 
First recorded activity by RadioBanter: Aug 2008
Posts: 14
Default How do I check if old coax is still usable?

Bill Horne wrote:
I have a run of RG-8 coax inside a conduit, and I'd like to keep it in
service if possible. How can I test it before I risk my finals trying to
put power into it?

It's OK AFAICT with a VOM.

73, Bill W1AC


Bill
Apply a megaohmmeter to test for any breakdown in the dialectic between
the center conductor and the shield and between the shield and ground.
A test voltage of 500 would be the highest I would go and I think three
hundred would tell you all there is to know about the integrity of the
insulation. You already know that the condition of the copper is
essentially unchanged.
--
Tom Horne

"This alternating current stuff is just a fad. It is much too dangerous
for general use." Thomas Alva Edison

  #3   Report Post  
Old September 30th 08, 07:04 PM posted to rec.radio.amateur.moderated
external usenet poster
 
First recorded activity by RadioBanter: Apr 2008
Posts: 543
Default How do I check if old coax is still usable?


"Tom Horne" wrote in message
...
Bill Horne wrote:
I have a run of RG-8 coax inside a conduit, and I'd like to keep it in
service if possible. How can I test it before I risk my finals trying to
put power into it?

It's OK AFAICT with a VOM.

73, Bill W1AC


Bill
Apply a megaohmmeter to test for any breakdown in the dialectic between
the center conductor and the shield and between the shield and ground.
A test voltage of 500 would be the highest I would go and I think three
hundred would tell you all there is to know about the integrity of the
insulation. You already know that the condition of the copper is
essentially unchanged.
--
Tom Horne

"This alternating current stuff is just a fad. It is much too dangerous
for general use." Thomas Alva Edison


Buried coax is prone to moisture unless the conduit was able to drain and
has air space. If you think it may have had moisture in it, replace it. I
like to replace at 10 years maximum because of contamination from the
chemicals in the dialectric.

  #4   Report Post  
Old October 3rd 08, 10:25 PM posted to rec.radio.amateur.moderated
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 877
Default How do I check if old coax is still usable?

On Sep 29, 5:11 pm, Bill Horne wrote:
I have a run of RG-8 coax inside a conduit, and I'd like to keep it in
service if possible. How can I test it before I risk my finals trying to
put power into it?


The simplest way I know is to use a QRP wattmeter and a dummy load.

First, set up a rig to feed the dummy load directly, through the dummy
load. Use the highest practical band (meaning what you have gear for).
Set your rig to deliver a few watts and record the exact reading,
forward and reflected. (By running low power you don't risk your rig,
and you test that the dummy and wattmeter work).

Then connect the rig and wattmeter to one end of the cable to be
tested, and the dummy load to the other end. Recheck the forward and
reflected power readings - they shouldn't be much different if the
cable is any good at all. (If you have any significant reflected power
when feeding the dummy load, it's clear the cable has water, an open
or a short someplace).

Finally move the wattmeter to the far end of the coax to be tested,
and put it just before the dummy load. Get one more set of forward and
reflected power readings. Compare with the readings when the wattmeter
is at the rig end of the cable. Compute the loss, convert it to dB,
and see how it compares to the expected value for the cable.

For example, suppose the cable is 50 feet of RG-8U and I do the test
on 40 meters. Suppose the wattmeter says 20 watts goes in but only 10
watts comes out, and almost no reflected power. That's half the power
(3 dB) lost in a cable that's supposed to be well under 1 dB per 100
feet at 7 MHz. Something's wrong.

73 de Jim, N2EY

  #5   Report Post  
Old October 5th 08, 09:59 PM posted to rec.radio.amateur.moderated
external usenet poster
 
First recorded activity by RadioBanter: Mar 2007
Posts: 8
Default How do I check if old coax is still usable?

O.M's
Bill simply try it satisfied use it disappointed use it as grounding wire
in all the replies of this subject is usefull stuff to experimentals
in practical sense chemical chances of the dielectrical between inner and
outer is telling
after 10 - 15 years depending the manifactor
In coastal envoriments the salt in the air reduce this
moisture between inner and outer is a silent dange rust reduce the
conductivity and moisture the impendance
Jim told you a way to measure some qualities I do the same when i got
unknown cable for JOTA use
A practcal tip old coaxcable is excelent to use as a dummyload
so again a lot of things to experiment
55 + 73 de PA0RAB ruud
schreef in bericht
...
On Sep 29, 5:11 pm, Bill Horne wrote:
I have a run of RG-8 coax inside a conduit, and I'd like to keep it in
service if possible. How can I test it before I risk my finals trying to
put power into it?


The simplest way I know is to use a QRP wattmeter and a dummy load.

First, set up a rig to feed the dummy load directly, through the dummy
load. Use the highest practical band (meaning what you have gear for).
Set your rig to deliver a few watts and record the exact reading,
forward and reflected. (By running low power you don't risk your rig,
and you test that the dummy and wattmeter work).

Then connect the rig and wattmeter to one end of the cable to be
tested, and the dummy load to the other end. Recheck the forward and
reflected power readings - they shouldn't be much different if the
cable is any good at all. (If you have any significant reflected power
when feeding the dummy load, it's clear the cable has water, an open
or a short someplace).

Finally move the wattmeter to the far end of the coax to be tested,
and put it just before the dummy load. Get one more set of forward and
reflected power readings. Compare with the readings when the wattmeter
is at the rig end of the cable. Compute the loss, convert it to dB,
and see how it compares to the expected value for the cable.

For example, suppose the cable is 50 feet of RG-8U and I do the test
on 40 meters. Suppose the wattmeter says 20 watts goes in but only 10
watts comes out, and almost no reflected power. That's half the power
(3 dB) lost in a cable that's supposed to be well under 1 dB per 100
feet at 7 MHz. Something's wrong.

73 de Jim, N2EY


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
BBC radio reception - how far from UK to be usable on medium wave? Pete L Shortwave 7 June 7th 10 12:37 PM
FS: Coax Connectors, Adapters & Bulk Coax Cable AAA RF Products Swap 1 December 20th 06 03:13 AM
Coax To Coax Noise transfer ? Robert11 Antenna 2 March 18th 06 09:16 PM
Frequency multipliers: Usable modulation formats? Joel Kolstad Homebrew 7 July 15th 05 01:31 AM
FS:RG8X 18 FT LENGTH COAX WITH COAX CONNECTOR Kb9igg Swap 0 October 31st 03 04:54 PM


All times are GMT +1. The time now is 01:04 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.