LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
Old October 15th 07, 08:55 PM posted to rec.radio.amateur.antenna
external usenet poster
 
First recorded activity by RadioBanter: Mar 2007
Posts: 3,521
Default Shunt loads on T-lines in EZNEC

On my web page at: http://www.w5dxp.com/G5RV.HTM
I show how to install a 1000 pf capacitor across
the G5RV transmission line at the twinlead/coax
junction to improve the 75m SWR and move the
resonant point into the 75m phone band.

I have never been able to model the shunt capacitor
with EZNEC. Anyone know of a way to do that?
--
73, Cecil http://www.w5dxp.com
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Reflection on Resistive loads palaniappan chellappan Antenna 23 August 1st 06 09:49 PM
Checkin' out dummy loads with a VNA... [email protected] Homebrew 12 May 1st 06 12:40 PM
MAKE LOADS OF MONEY FOR FREE Dr.Ace - WH2T General 0 July 27th 05 02:57 PM
EZNEC ARRL and EZNEC 4 Demo: Setting default folders Buck Antenna 2 June 16th 05 01:33 AM
Oil for dummy loads Javier Henderson Antenna 33 August 20th 03 08:16 PM