Ed wrote:
Run a metal snake into the conduit then get a metal detector and sweep the area for the conduit. If this doesn't work there are wire tracing detectors that might do the job. You hook the transmitter to the snake and sweep with the detector. If all fails you might try a metal probe. Stick the probe into the ground and feel for the conduit. Or dig up a couple of feet of conduit. Note the direction it is going then move in that direction and dig a small trench where you thing the conduit is. One of these methods should work. If all fails install new conduit. Dave WD9BDZ Dave, your idea above, plus some comments from others has made me realize that this is the way I should proceed, for my first attempt. I do have a Service Monitor. I'll simply run my snake into the empty pvc conduit until it hits the end ( duct tape ) and connect an RF signal to it, then using a small HT, track the signal down to the end. My thanks to all for other ideas presented here, too. Ed K7AAT Ed; Thanks for the compliment. I wish you luck and envy you for your acreage for antenna's. My lot here in St. Louis is something like 40 feet by 120 feet with the house in the center. I do have some trees along the back alley that I have wire hanging from. Works but not optimal. Let us know how everything works out. Dave WD9BDZ |
#2
![]() |
|||
|
|||
![]()
Plumbers power snake for sewers... Rent it at the rent it shop... It
will auger up through that duct tape and sand like it is tissue paper... denny/ k8do |
#3
![]() |
|||
|
|||
![]()
On Thu, 16 Oct 2008 06:36:34 -0700 (PDT), Denny
wrote: Plumbers power snake for sewers... Rent it at the rent it shop... It will auger up through that duct tape and sand like it is tissue paper... denny/ k8do Ummm.... this is through 3/4" schedule 40 PVC with at least two right angles. The augers I've seen are for much larger sewer drain pipe and will not fit inside 3/4" PVC. Anything that can drill through sand can probably also do some real damage to the PVC. A much smaller diameter "snake" is probably safer. With only 1ft of sand to push through, a solid "tape" type electricians snake can be pushed through by hand. The only down side is that the pipe will fill with sand when the duct tape is breached, so cleanup may be a problem. If dry sand, a small hose on the end of a vacuum cleaner should work. Incidentally, the frequencies used by commerical cable finders are 815Hz, 8Khz, and 82KHz at 2-3 watts. http://www.rycominstruments.com/3-8879-Cable-Utility-Locator.asp However, that's good for 15 ft depth and many miles of cable. Higher frequencies will probably work for 1ft of sand and only 100ft of wire. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#4
![]() |
|||
|
|||
![]()
Ummm.... this is through 3/4" schedule 40 PVC with at least two right
angles. The augers I've seen are for much larger sewer drain pipe and will not fit inside 3/4" PVC. Anything that can drill through sand Ouch! Unless you are trying to fish a phone line, you (might/might not/want) WILL dig it all up and go to 2" with 45 degree bends and bevel the inside edges. Once above ground you can break out to pull boxes. You have my sympathy. |
#5
![]() |
|||
|
|||
![]()
On Thu, 16 Oct 2008 16:37:22 GMT, "JB" wrote:
Ummm.... this is through 3/4" schedule 40 PVC with at least two right angles. The augers I've seen are for much larger sewer drain pipe and will not fit inside 3/4" PVC. Anything that can drill through sand Ouch! Unless you are trying to fish a phone line, you (might/might not/want) WILL dig it all up and go to 2" with 45 degree bends and bevel the inside edges. Once above ground you can break out to pull boxes. You have my sympathy. Thanks for the sympathy but it's not my conduit or problem. The plumbing belongs to Ed, K6AAT. Question: What's the difference between conduit and plumbing? Answer: Plumbing holds water. Otherwise, they're the same. I'm not sure what might be going inside a 3/4" conduit, but if it's for a tower, it's way too small. The original question does not indicate what manner of wiring goes inside. With 3/4", you can get perhaps one run of LMR400 plus some flat rotator cable and you're full. Hard to tell from here. It's also possible to place a diplexer (or triplexer) at both ends of the single coax run for splitting out HF, VHF, and UHF. I've done that when running multiple coax cables was impossible. http://www.rfparts.com/diamond/Product_Catalog/plexers.html It's been a long time since I've done any tower construction, but for commercial installs, I never used buried coax runs. AC power for the tower lights were in 3" steel threaded conduit (not EMT), but the coax was all above ground. That shortened the coax runs about 25ft which was well worth the effort. Incidentally, a good trick is to *NOT* lay the conduit perfectly horizontally plumb. Put one end lower than the other so that water well drain into that end. Shove a PEX sprinkler line down to the low point of pipe and pump out the water once a year. I prefer pressurized conduit, but a water sump works fairly well. I discovered, the hard way, why using steel pipe instead of PVC was a good idea. With everything underground, the obvious parking location for the crane, cherry picker, or propane truck was directly on top of the buried PVC. After a few cracked pipes, I decided that steel was a good idea. I like to pressurize the conduit slightly to keep the water out. It's really not necessary as most coax will survive when immersed. However, everyone re-uses coax, which has cuts in the outer jacket, and which might not be fully waterproof. A pressure gauge, bicycle valve, bicycle pump, some putty, and a few PSI are good enough. I almost forgot.... a slow death to the installer that shoved a coax barrel splice down a stuffed conduit, thus insuring that all subsequent coax runs will jam up against the coax connectors. Also, this is what happens when a monopole tower is stuffed full of coax cables, and some idiot decides to enlarge the hole with a cutting torch. http://802.11junk.com/jeffl/pics/drivel/slides/monopoleBurn.html http://odessaoffice.com/wireless/priceless.jpg -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |