#32
![]() |
|||
|
|||
![]()
On Oct 23, 12:02*am, "Jerry" wrote:
"JIMMIE" wrote in message ... On Oct 15, 1:17 am, Ed wrote: I know this is slightly off topic, but since I am intending to run some RF cable in the conduit, and since there are a lot of intelligent hams on this group, I will proceed anyway: Last year at the beginning of construction of a new house I buried about 50 feet of 3/4" Sched. 40 PVD between the house and a location on the property perimeter. Now that I am ready to use it, I can not locate the perimeter end.... it is somewhere in about a 10' area, and the end curves up to probably about a foot underground. The ground is nearly pure sand, and is well landscaped now to the point that I do not want to randomly dig it up. The end terminated in an elbow curving up and is well duct taped shut. Can anyone suggest a method or equipment I might use to locate that far end? Tnx. Ed K7AAT I have some pipe that I had run for an outdoor spigot that I never finished installing. *To test a method of finding it I shot some air into it the other end was pretty easy to find by listening. I could hear the rush of air and a lot of gurgling. My dog actually found it in the roses bushes before I did. Jimmie * Hi Jimmie * That "air" idea wont work, Jeff told me so * Quote Jeff -- "Welcome to rec.radio.amateur.antenna.physics Ok, let's do the math. *Dry sand weighs 100 lb/cubic-foot. *There's about 1 ft of sand above the end of the 3/4" conduit. *The weight action is roughly conical, so the volume of sand involved is (my guess) about: * 100 lbs/ft^3 * 1/3 = 33 lbs of sand. All that it acting on a 3/4" diameter pipe, with a cross sectional area of about: * Pi * 0.75" = 2.4 in^2 Therefore, the pressure exerted by the sand is: * 33 lbs / 2.4 in^2 = 14 PSI So, if he can pressurize the pipe to more than 14 PSI, he can lift the column of sand sufficiently to keep it from dribbling into the pipe. Of course, it's not that simple. *Laminar air flow, pressure gradients across the conduit, and the effects of the duct tape will ruin my simplistic guesswork. *Worse, the back pressure created by the immovable column of sand will force some sand particles into the conduit around the edges with the "reflected" air pressure. *In the middle of the conduit, the air flow is all out of the conduit, but near the edges, it could easily be the other direction. *I'm also assuming that the sand is a perfect air seal, which it's not. *To prevent all this from happening, the minimum air pressure should be about twice the 14 PSI, which is easily achievable with an air compressor, but not a vacuum cleaner. I'm also trying to imagine how the process will work. *I see an air compressor pumping madly away as the neighbors kids furiously dig around the resultant sand volcano, as sand rapidly refills the conical hole. *In my never humble opinion, there's no way to prevent sand from dropping into the conduit if the duct tape seal is broken before excavating the end of the conduit. Once the sand is in the conduit, just blowing air through the pipe isn't going to magically elevate the sand particles 1ft or more in the air. *The air does not have sufficient mass to convey enough momentum to move the sand particles, much less eject them vertically. *For that, one needs a denser medium, such as water. *Shoving a plunger through might work, but it's equally likely to jam sand particles into the PVC conduit walls. -- Jeff Liebermann * * 150 Felker St #D * *http://www.LearnByDestroying.com Santa Cruz CA 95060http://802.11junk.com Skype: JeffLiebermann * * AE6KS * *831-336-2558" * * * * *Jerry * KD6JDJ- Hide quoted text - - Show quoted text - Obviously you're an engineer. LOL Jimmie |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Locating the source of a number station | Shortwave | |||
Antenna cables in metallic conduit? | Antenna | |||
Underground Bases | Shortwave | |||
Pulling Cable in Conduit | Antenna | |||
Underground antennas | Shortwave |