Home |
Search |
Today's Posts |
#10
![]() |
|||
|
|||
![]()
Bob wrote in
: Anyone know the velocity factor of JSC #1317 450 ohm line, 18 AWG? Googling seems to give a variety of answers, and it's not posted at the JSC site. Wes, N7WS, measured some Wireman lines similar to that above. His measurements indicated Zo quite different to nominal, and velocity factor around 0.9. For applications where velocity factor is important, eg the 'matching section' of a G5RV, I suggest you measure the actual cable. Wes's data is included in TLLC (http://www.vk1od.net/calc/tl/tllc.php). Your cable has similar stranding to Wireman 551, but velocity factor will depend on the detail of the dielectric extrusion and punching. If JSC is the manufacturer, they may even be the source of Wireman lines, in which case Wes's data may be directly applicable. I have reservations about the adequacy of copper cladding on the cable such as yours at the lower end of HF. Owen |