I only just saw your post this afternoon, but before you replace the timer
board, check to see if there is a limit switch in the blower compartment, and see if there is a reset for it. If this doesn't work, connect a jumper across it and see if that works. If that doesn't do the trick, look for other limit switches and do the same for those. You may not need to replace the timer board after all. Let us know what you find out please. Bob KB2ZGN On Tue, 20 Dec 2011 08:47:38 -0500, " Tuuk" wrote: Hi Thanks for all the advice. And I have tried all those. I took the condensing fan blower out and cleaned out that housing behind it and re-siliconed it. It did have some gunk in there but not enough to cause a clog. But now that is clean and when I reinstalled it the exact same thing happened. What is troubling me is that even if the thermost wires are disconnected from that board what happens is both man blower and exhast blower simply are the only things that run. Instantly. No sequence of events eg blower starting, then ignigters starting then main blower after heat exchangers heats up. None of that. I jumped that float switch and those vacume hoses I sucked and blew through them and I can hear the switches working, but same thing happens, nothing happens with that honeywell smart valve, no gas. I checked all the intake air pipes and exhaust pipes, nothing clogging. While everything leads me to believe it is the board so I bought another for 80 dollars and will replace that board today. I will take a photo of the board and one by one replace those wired and connections and try that. I was hitting those relays on the board and still nothing. Seems some are upset because of my posts of my antenna and my sauna and garden,,,, well coincedently enough I have in my basement the sauna and steam bath thing I also installed and it was that very night that me and the missis were steaming it up in the sauna and steam bath and I think maybe there was moisture in the air that evening as that was the evening it failed. To answer a question about the lights, my friend's furnace has the idiot lights where it blinks signifying what has failed, mine has no lights on that board, I think mine was the model before his, mine is about ten years old. I am going to replace this main fan relay board and see if that solves the problem, I can return the board if the same problem remains and start replacing the next part after that until something works right. I replaced the thermostat with the old one and same problem. Thanks for the advice and tips. As I have said, I know there is a lot of knowledge in this group, I have benefited from it before and will again, as my server doesn't have active newsgroups like HVAC or Furnace or any of the other crazy things I have asked about. Lots of knowledge here, thanks. And i cannot wait until someone asks a question about their furnace, or their sauna rocks, or their tower, or their garden,,, because I will be the first to answer. 73 |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|