LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #6   Report Post  
Old March 10th 07, 04:33 PM posted to rec.radio.amateur.boatanchors
external usenet poster
 
First recorded activity by RadioBanter: Jul 2006
Posts: 444
Default nc-140 running hot

wrote:

On Mar 9, 5:00 pm, wrote:

What is generally indicated when a power transformer is very hot, and
the 7w power transistor in its vicinity is also very hot? The radio
works but will often "go quiet" after 10 minutes or so of operation.
Any suggestions would be greatly appreciated.
Pete



I meant resistor, not transistor


There are two likely situations as to why a transformer runs 'hot'. The remedies
have been briefly discussed. Let me add some background.

First, the design of the transformer uses a magnetic material that is
non-linear. As the magnetizing force is increased to higher levels the B-H curve
goes sub linear and the cores starts to saturate [the self inductance decreases]
and more primary current is drawn into the transformer [more heat].

The transformer equation for 60 Hz sine waves is E = 4.44*f*N*B*A. Where f
equals line frequency, N equals the number of turns on the primary, B equals
flux density, and A equals cross sectional area of the core primary. Since f, N
and A are fixed, an increase of voltage requires an increase in flux density
[b]. B equals the permeability [u] time the magnetizing force [H]. The value u
is very non linear and decreases in transformer material as H is increased to
higher values above the 'linear' region.

Conclusion, transformer get hot. Solution: reduce the primary voltage as
suggested in other responses.

Second, older designed electrolytic capacitors used a 'wet' dielectric. Simply
because capacitors get old [don't we all] the degree of 'wetness' dries out and
the dielectric dissipation factor increases. The capacitors, in common language,
become lossy. The isolation resistance can change from millions of ohms to a
value of a few tens of ohms.

Conclusion, I^2*R losses increase in the lower [lossier] resistance. Some
capacitors can be reformed. If there is large design margin, spec value divided
by stress value [eg; 450 VDC rating/200 VDC operating condition], then it is
possible to 'reform' the capacitor by gradually increasing the operating voltage.

Preferably, the older electrolytic capacitors should be replaced.

Either or both situations should be checked to assure that the 'hot' transformer
is not over stressed.

Note: transformers typically run at 95 percent efficient. So, some heating is
normal.

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
WJR not running IBOC? Ron Hardin Shortwave 16 February 24th 07 02:12 AM
DX is running a bit Steveo CB 6 November 21st 06 12:54 AM
DX running I AmnotGeorgeBush CB 9 May 28th 06 06:58 AM
BC-229 up and running. Steven Swift Boatanchors 6 October 21st 05 12:28 AM
DX running today Twistedhed CB 9 September 14th 03 03:41 AM


All times are GMT +1. The time now is 02:50 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017