Home |
Search |
Today's Posts |
|
#1
![]() |
|||
|
|||
![]() Gary Schafer ) writes: Check your counter specs. Some will take 1, 5 or 10 mhz time base without doing anything. 73 Gary K4FMX That's a good point. Given that they will all divide the timebase down to a very low frequency, even if there's nothing specific one could likely tap higher up on the divider chain. Michael VE2BVW On Fri, 27 Aug 2004 07:32:37 GMT, (Mike W) wrote: GM Folks, My 10Mhz TCXO that I use for a frequency counter timebase has gone toes up and I only have a 5Mhz one available to replace it. Can anyone offer ideas to double the 5 Mhz TCXO keeping the M:S ratio accurate enough for use with the frequency counter ?. The 5Mhz TCXO has an output of 2v P-P sinewave into 50R and I need TTL level 50:50 M:S at 10Mhz. Thanks, Mike W |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Phase frequency Detector | Homebrew |