Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Old January 18th 05, 03:26 PM
Henry Kolesnik
 
Posts: n/a
Default Kenwood PS-40 switching PS ?

This is a 20 amp switching power supply for their 12 volt ham transceivers.
I used to leave it on 24 hours a day on receive pulling less than an amp
with no problems but about a month ago it started to shut off. You have to
turn it off first and wait about 15 minutes and it'll come back on,
sometimes for an hour or longer and other times for 5 to 10 minutes. After
it goes down you have to turn it off and then wait 10 to 15 and it'll come
back for an unpredictable time. It doesn't seem matter if it been on for an
hour or sometime 5 minutes, it'll shut down. It doesn't seem to be a cold or
heat problem and flexing the board or tapping components won't turn it off
or make it come on quicker. I don't have a schematic and can't find one.
It must have some kind of logic that senses something and makes it shut down
and then time out. One thing I have noticed is that if I turn it on when
its not ready to come on I can hear a very, very faint noise (like static
discharge) that goes away as soon as the switch is turned off. It has a
TL494CN. Any tips appreciated.

--

73
Hank WD5JFR


  #2   Report Post  
Old January 18th 05, 06:59 PM
sofie
 
Posts: n/a
Default

Henry:
As long as it is still w"working" the problem is not likely anything more
than either cold or cracked solder connection OR electrolytics that have
dried out or have developed high ESR. If you do not have an ESR meter then
you will have to use the "one by one" substitution method... or just replace
all of the electrolytics at once. Just about all other methods of testing
electrolytics will not provide the crucial ESR test needed especially for
electrolytics in switching power supplies and other high frequency or
critical circuitry.
DO NOT keep running your power supply with this problem.... it will only get
worse to the point that it will fail all together and be a much more
involved repair.
--
Best Regards,
Daniel Sofie
Electronics Supply & Repair
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -



"Henry Kolesnik" wrote in message
om...
This is a 20 amp switching power supply for their 12 volt ham

transceivers.
I used to leave it on 24 hours a day on receive pulling less than an amp
with no problems but about a month ago it started to shut off. You have

to
turn it off first and wait about 15 minutes and it'll come back on,
sometimes for an hour or longer and other times for 5 to 10 minutes.

After
it goes down you have to turn it off and then wait 10 to 15 and it'll come
back for an unpredictable time. It doesn't seem matter if it been on for

an
hour or sometime 5 minutes, it'll shut down. It doesn't seem to be a cold

or
heat problem and flexing the board or tapping components won't turn it

off
or make it come on quicker. I don't have a schematic and can't find one.
It must have some kind of logic that senses something and makes it shut

down
and then time out. One thing I have noticed is that if I turn it on when
its not ready to come on I can hear a very, very faint noise (like static
discharge) that goes away as soon as the switch is turned off. It has a
TL494CN. Any tips appreciated.

--

73
Hank WD5JFR




  #3   Report Post  
Old January 18th 05, 07:40 PM
Henry Kolesnik
 
Posts: n/a
Default

The power supply was turned on this morning at 8 am and shut down in less
than 10 minutes. I turned it back on about 9:30 and it is still on, that's
over 4 hours. I'm not that versed on ESR but I have a tester and cm
curious if high ESR can be an intermittent condition and if so what would
the physics of that phenomena be? At this point I'm not willing to do a
shotgun replacement of all the caps. I do keep running the power supply and
the condition is not getting worse. I wish it would fail so I might find
the failed component. The way it is now it's impossible to troubleshoot
without shotgunning.

--

73
Hank WD5JFR
"sofie" wrote in message
...
Henry:
As long as it is still w"working" the problem is not likely anything more
than either cold or cracked solder connection OR electrolytics that have
dried out or have developed high ESR. If you do not have an ESR meter
then
you will have to use the "one by one" substitution method... or just
replace
all of the electrolytics at once. Just about all other methods of
testing
electrolytics will not provide the crucial ESR test needed especially for
electrolytics in switching power supplies and other high frequency or
critical circuitry.
DO NOT keep running your power supply with this problem.... it will only
get
worse to the point that it will fail all together and be a much more
involved repair.
--
Best Regards,
Daniel Sofie
Electronics Supply & Repair
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -



"Henry Kolesnik" wrote in message
om...
This is a 20 amp switching power supply for their 12 volt ham

transceivers.
I used to leave it on 24 hours a day on receive pulling less than an amp
with no problems but about a month ago it started to shut off. You have

to
turn it off first and wait about 15 minutes and it'll come back on,
sometimes for an hour or longer and other times for 5 to 10 minutes.

After
it goes down you have to turn it off and then wait 10 to 15 and it'll
come
back for an unpredictable time. It doesn't seem matter if it been on for

an
hour or sometime 5 minutes, it'll shut down. It doesn't seem to be a cold

or
heat problem and flexing the board or tapping components won't turn it

off
or make it come on quicker. I don't have a schematic and can't find one.
It must have some kind of logic that senses something and makes it shut

down
and then time out. One thing I have noticed is that if I turn it on when
its not ready to come on I can hear a very, very faint noise (like static
discharge) that goes away as soon as the switch is turned off. It has a
TL494CN. Any tips appreciated.

--

73
Hank WD5JFR






  #4   Report Post  
Old January 18th 05, 08:27 PM
Tim Wescott
 
Posts: n/a
Default

Henry Kolesnik wrote:

The power supply was turned on this morning at 8 am and shut down in less
than 10 minutes. I turned it back on about 9:30 and it is still on, that's
over 4 hours. I'm not that versed on ESR but I have a tester and cm
curious if high ESR can be an intermittent condition and if so what would
the physics of that phenomena be? At this point I'm not willing to do a
shotgun replacement of all the caps. I do keep running the power supply and
the condition is not getting worse. I wish it would fail so I might find
the failed component. The way it is now it's impossible to troubleshoot
without shotgunning.

A dried out cap is not an intermittent problem, but if the supply turns
off when some threshold is reached and that threshold has lowered
because of the cap's high ESR then the actual trigger would be caused by
power line fluctuations, temperature changes, etc.

A cold solder joint would be quite intermittent, but it would show up
with board flexing and other "wiggling" kind of diagnostics.

--

Tim Wescott
Wescott Design Services
http://www.wescottdesign.com
  #5   Report Post  
Old January 18th 05, 08:47 PM
Jerry G.
 
Posts: n/a
Default

Do an ESR test on the caps. Chances are you will only have a number of bad
caps. Sometimes it is best to cool and heat the caps under test. I use a
heatgun, and freeze spray to cool and heat them.

--

Jerry G.
======


"Henry Kolesnik" wrote in message
om...
This is a 20 amp switching power supply for their 12 volt ham transceivers.
I used to leave it on 24 hours a day on receive pulling less than an amp
with no problems but about a month ago it started to shut off. You have to
turn it off first and wait about 15 minutes and it'll come back on,
sometimes for an hour or longer and other times for 5 to 10 minutes. After
it goes down you have to turn it off and then wait 10 to 15 and it'll come
back for an unpredictable time. It doesn't seem matter if it been on for an
hour or sometime 5 minutes, it'll shut down. It doesn't seem to be a cold or
heat problem and flexing the board or tapping components won't turn it off
or make it come on quicker. I don't have a schematic and can't find one.
It must have some kind of logic that senses something and makes it shut down
and then time out. One thing I have noticed is that if I turn it on when
its not ready to come on I can hear a very, very faint noise (like static
discharge) that goes away as soon as the switch is turned off. It has a
TL494CN. Any tips appreciated.

--

73
Hank WD5JFR





  #6   Report Post  
Old January 19th 05, 12:01 AM
 
Posts: n/a
Default

Henry Kolesnik wrote:
snipped:
At this point I'm not willing to do a
shotgun replacement of all the caps. I do keep running the power

supply and
the condition is not getting worse. I wish it would fail so I might

find
the failed component. The way it is now it's impossible to

troubleshoot
without shotgunning.




Henry:
Looking for cracked circuit board connections AND testing the
electrolytics with an ESR meter (or substituting electrolytics if you
do not have an ESR meter) is NOT "shotgunning".... it is real
troubleshooting advice as a result of the symptoms you posted. If you
continue to use it with the problem you reported it may fail completely
and be a bigger repair job.
Pay a little now Or pay a lot later.
electricitym

  #7   Report Post  
Old January 19th 05, 05:05 PM
Henry Kolesnik
 
Posts: n/a
Default

As of this moment it has run over 26 hours without shutting down. I've
never seen any evidence that ESR can be an intermittent phenomena. Can
someone please tell me how intermittent ESR comes about?

--

73
Hank WD5JFR
wrote in message
oups.com...
Henry Kolesnik wrote:
snipped:
At this point I'm not willing to do a
shotgun replacement of all the caps. I do keep running the power

supply and
the condition is not getting worse. I wish it would fail so I might

find
the failed component. The way it is now it's impossible to

troubleshoot
without shotgunning.




Henry:
Looking for cracked circuit board connections AND testing the
electrolytics with an ESR meter (or substituting electrolytics if you
do not have an ESR meter) is NOT "shotgunning".... it is real
troubleshooting advice as a result of the symptoms you posted. If you
continue to use it with the problem you reported it may fail completely
and be a bigger repair job.
Pay a little now Or pay a lot later.
electricitym



  #8   Report Post  
Old January 19th 05, 05:34 PM
Sam Goldwasser
 
Posts: n/a
Default

You should at least test the electrolytic caps in the startup circuit.

Since as I recall, it blows up only when applying AC power suddenly, something
funny is going on during startup.

--- sam | Sci.Electronics.Repair FAQ Mirror: http://repairfaq.ece.drexel.edu/
Repair | Main Table of Contents: http://repairfaq.ece.drexel.edu/REPAIR/
+Lasers | Sam's Laser FAQ: http://repairfaq.ece.drexel.edu/sam/lasersam.htm
| Mirror Sites: http://repairfaq.ece.drexel.edu/REPAIR/F_mirror.html

Note: These links are hopefully temporary until we can sort out the excessive
traffic on Repairfaq.org.

Important: Anything sent to the email address in the message header above is
ignored unless my full name is included in the subject line. Or, you can
contact me via the Feedback Form in the FAQs.


"Henry Kolesnik" writes:

As of this moment it has run over 26 hours without shutting down. I've
never seen any evidence that ESR can be an intermittent phenomena. Can
someone please tell me how intermittent ESR comes about?

--

73
Hank WD5JFR
wrote in message
oups.com...
Henry Kolesnik wrote:
snipped:
At this point I'm not willing to do a
shotgun replacement of all the caps. I do keep running the power

supply and
the condition is not getting worse. I wish it would fail so I might

find
the failed component. The way it is now it's impossible to

troubleshoot
without shotgunning.




Henry:
Looking for cracked circuit board connections AND testing the
electrolytics with an ESR meter (or substituting electrolytics if you
do not have an ESR meter) is NOT "shotgunning".... it is real
troubleshooting advice as a result of the symptoms you posted. If you
continue to use it with the problem you reported it may fail completely
and be a bigger repair job.
Pay a little now Or pay a lot later.
electricitym

  #9   Report Post  
Old January 19th 05, 06:35 PM
sofie
 
Posts: n/a
Default

Henry Kolesnik:
It is NOT "intermittent ESR" that is the problem, rather it is that maybe
some electrolytics have developed high ESR and are operating just at or near
the threshold of the circuitry operating correctly... (see the reply post
from Tim Wescott).
At this point you have been given sound technical advice to check for
circuit board solder connections and to suspect the electrolytics......
until you perform this important initial suggested troubleshooting there is
not much more that you can do ??? Get this fixed right away before it
fails completely as you have previously been cautioned.
electricitym


"Henry Kolesnik" wrote in message
news
As of this moment it has run over 26 hours without shutting down. I've
never seen any evidence that ESR can be an intermittent phenomena. Can
someone please tell me how intermittent ESR comes about?



  #10   Report Post  
Old January 19th 05, 06:51 PM
Tim Wescott
 
Posts: n/a
Default

Henry Kolesnik wrote:

As of this moment it has run over 26 hours without shutting down. I've
never seen any evidence that ESR can be an intermittent phenomena. Can
someone please tell me how intermittent ESR comes about?

Who ever said ESR had to be intermittent to cause intermittent problems?

--

Tim Wescott
Wescott Design Services
http://www.wescottdesign.com
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
fs: Kenwood kpt50 repeater radio programmer Skipp has Kenwood stuff Homebrew 2 August 14th 20 06:12 PM
fs: Kenwood kpt50 repeater radio programmer Skipp has Kenwood stuff Equipment 2 June 16th 06 04:22 PM
fs: Kenwood kpt50 repeater radio programmer Skipp has Kenwood stuff Equipment 0 August 7th 03 06:16 PM
fs: Kenwood kpt50 repeater radio programmer Skipp has Kenwood stuff Homebrew 0 August 7th 03 06:16 PM
Address the issues, Skippy! Repost #3 Skipp would rather be back in Tahoe CB 5 July 30th 03 07:05 PM


All times are GMT +1. The time now is 04:16 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017