  #41   Report Post  
Old December 22nd 03, 07:50 PM
Harvey Babb
 
Posts: n/a
Default

While you're at it, check one more thing! If the problem turns out to be
welded contacts on the thermostat switch, check that the MOV across the
secondary of the transformer is still good. I had one that repeatedly
welded the contacts till I replaced the MOV and has worked for 5 years
now without a problem.

Joshua G Senecal wrote:

On Fri, 19 Dec 2003, G.Beat wrote:
Wow, I didn't think that my question would generate so many responses!
Thanks everyone for your input.


The Red-Glow tells you 2 things:

1. The heater (Weller EC234) is still working (but you are shortening its
life operating in this manner - cherry red)


Well, I don't operate with it cherry red. This is the first time it's done
that--hence my knowing that something is amiss.


2. The WTCP series temperature control (which works with the "PT" tip and
the SW60 switch) is not working properly.


Recommend: Change tips. Improper tips will cause this problem.
Get a Weller PTA7 (which is the standard tip shipped with this iron).
The barrel net (BA-60 may also require replacement.


I'll take a look and see. The station came with two tips, both #7, but in
the 11-odd years I've owned the iron I've never used the second one.


I also have the Weller Tech Sheet for this model -- if you need
a copy. This has part numbers, diagrams and troubleshooting advice (shipped
with every unit new)


Actually, I would like a copy, thank you. Since I got mine at a yard sale
I don't have any documentation. Please e-mail to
, removing the reversed "nospam" first.

-Josh, AE6IQ



  #42   Report Post  
Old December 22nd 03, 09:40 PM
Frank Dinger
 
Posts: n/a
Default

While you're at it, check one more thing! If the problem turns out to be
welded contacts on the thermostat switch, check that the MOV across the
secondary of the transformer is still good. I had one that repeatedly
welded the contacts till I replaced the MOV and has worked for 5 years
now without a problem.

=============================
Not having such a Weller soldering iron myself ,nevertheless I am interested
in the MOV (firing) voltage against the normal operating voltage . Also , is
it DC or AC ?

Frank GM0CSZ / KN6WH





  #43   Report Post  
Old December 22nd 03, 09:40 PM
Frank Dinger
 
Posts: n/a
Default

While you're at it, check one more thing! If the problem turns out to be
welded contacts on the thermostat switch, check that the MOV across the
secondary of the transformer is still good. I had one that repeatedly
welded the contacts till I replaced the MOV and has worked for 5 years
now without a problem.

=============================
Not having such a Weller soldering iron myself ,nevertheless I am interested
in the MOV (firing) voltage against the normal operating voltage . Also , is
it DC or AC ?

Frank GM0CSZ / KN6WH





  #44   Report Post  
Old December 23rd 03, 03:50 AM
Harvey Babb
 
Posts: n/a
Default

The MOV (Metal Oxide Varistor) is a surge supressor whose only function
is to absorb the "kick" when the mechanical thermostat opens (or
"bounces" when closing). The one in the Weller unit (if memory serves)
clamps the voltage at about 40 volts (Transformer secondary is 24 VAC).
If it isn't working properly the thermostat contacts arc and weld shut,
causing runaway overheating.

Frank Dinger wrote:

While you're at it, check one more thing! If the problem turns out to be
welded contacts on the thermostat switch, check that the MOV across the
secondary of the transformer is still good. I had one that repeatedly
welded the contacts till I replaced the MOV and has worked for 5 years
now without a problem.

=============================
Not having such a Weller soldering iron myself ,nevertheless I am interested
in the MOV (firing) voltage against the normal operating voltage . Also , is
it DC or AC ?

Frank GM0CSZ / KN6WH







  #45   Report Post  
Old December 23rd 03, 03:50 AM
Harvey Babb
 
Posts: n/a
Default

The MOV (Metal Oxide Varistor) is a surge supressor whose only function
is to absorb the "kick" when the mechanical thermostat opens (or
"bounces" when closing). The one in the Weller unit (if memory serves)
clamps the voltage at about 40 volts (Transformer secondary is 24 VAC).
If it isn't working properly the thermostat contacts arc and weld shut,
causing runaway overheating.

Frank Dinger wrote:

While you're at it, check one more thing! If the problem turns out to be
welded contacts on the thermostat switch, check that the MOV across the
secondary of the transformer is still good. I had one that repeatedly
welded the contacts till I replaced the MOV and has worked for 5 years
now without a problem.

=============================
Not having such a Weller soldering iron myself ,nevertheless I am interested
in the MOV (firing) voltage against the normal operating voltage . Also , is
it DC or AC ?

Frank GM0CSZ / KN6WH









  #46   Report Post  
Old December 23rd 03, 02:32 PM
Frank Dinger
 
Posts: n/a
Default


"Harvey Babb" wrote :
The MOV (Metal Oxide Varistor) is a surge supressor whose only function
is to absorb the "kick" when the mechanical thermostat opens (or
"bounces" when closing). The one in the Weller unit (if memory serves)
clamps the voltage at about 40 volts (Transformer secondary is 24 VAC).
If it isn't working properly the thermostat contacts arc and weld shut,
causing runaway overheating.

==========================
Harvey , Tnx for the useful info . I was interested in the spike voltage
suppression level of the MOV, which is required since the heater element is
for AC . In the event of DC a reversely connected diode would have done the
trick .

Frank GM0CSZ / KN6WH


  #47   Report Post  
Old December 23rd 03, 02:32 PM
Frank Dinger
 
Posts: n/a
Default


"Harvey Babb" wrote :
The MOV (Metal Oxide Varistor) is a surge supressor whose only function
is to absorb the "kick" when the mechanical thermostat opens (or
"bounces" when closing). The one in the Weller unit (if memory serves)
clamps the voltage at about 40 volts (Transformer secondary is 24 VAC).
If it isn't working properly the thermostat contacts arc and weld shut,
causing runaway overheating.

==========================
Harvey , Tnx for the useful info . I was interested in the spike voltage
suppression level of the MOV, which is required since the heater element is
for AC . In the event of DC a reversely connected diode would have done the
trick .

Frank GM0CSZ / KN6WH


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
new 2m repeater on space station g3zhi Boatanchors 0 September 13th 04 11:18 AM
Amateur Radio Newsline™ Report 1400 ­ June 11, 2004 Radionews Dx 0 June 16th 04 08:34 PM
Amateur Radio Newsline™ Report 1400 ­ June 11, 2004 Radionews Dx 0 June 16th 04 08:34 PM
Weller station gone bad--how to fix? Joshua G Senecal Equipment 46 December 23rd 03 02:32 PM
Weller station gone bad--how to fix? Joshua G Senecal Equipment 0 December 18th 03 04:32 PM


All times are GMT +1. The time now is 11:13 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 RadioBanter.
The comments are property of their posters.
 

About Us

"It's about Radio"

 

Copyright © 2017