Home |
Search |
Today's Posts |
#8
![]() |
|||
|
|||
![]()
In article ,
RadioGuy wrote: However, if the dovetails are altered (redesign of the injection mold) the connectors can be oriented 'on top of ' as opposed to the current 'side by side' orientation ---the new design will then allow the connectors halves to mate only ONE way. The connectors will no longer be 'mirrored' and as the 'PowerPole' connectors do not posess a gender a standard will be required regarding which connector half is used for the supply side and which is used for the equipment side. This would eliminate the perceived (and actual) benefit of having a genderless arrangment, which lets you plug a battery into a radio (acting as a supply) or into a charger or power supply (acting as a load, for recharging), or into a distribution panel alongside radio connections (acting as a floating backup to a mains-powered supply). It is highly unlikely that Anderson will redesign the 'PowerPole' connector to meet the needs of the Ham community. Agreed. It amazes me that this connector, with the potential of short-circuit from misalignment, could be considered a standard for power connections of emergency communications equipment. The PowerPoles have been around for quite a while, and have seen a lot of use in fields other than ham radio. I'm curious as to whether you can cite evidence that the problem you forsee, actually occurs in practice? In review of the literature no mention is made of the possibility of improperly mating of these connectors. This must be the first time in my experience that equipment and power source must be fused to prevent a short-circuit resulting from improper connector mating---unbelievable. All power sources must be fused, in any case, in order to provide protection against short circuits. In a mobile setting, it's canon that both the hot and neutral should be fused, as close to the battery as possible, in order to avoid dangerous ground-wire currents if the alternator ground wire pops loose from the battery. I'm not convinced that the PowerPole arrangement requires any additional fusing, above and beyond what's normal and appropriate for ham gear. Proper fusing on the hot side of the source ought to be sufficient to result in an immediate fuse-blow under any PowerPole misconnection arrangment I've been able to envision. As I see it, if a PowerPole set is correctly wired, there are four ways to try to mate it. One is correct, and works. One has the connectors rotated 180 degrees out of phase - doesn't mate, no problem. One way has them rotated correctly, but offset in one direction - radio's "hot" goes to supply ground, radio's ground is unconnected (or occurs via the antenna or chassis mount). This one seems completely benign, as the radio is connected only to ground - radio doesn't power up, but there seems to be no potential for damage. The fourth case is the only arguably problematic one, as it connects the supply hot to the radio ground. This seems very likely to blow the supply fuse, either instantly or the moment the radio chassis touches ground. I don't see the need for a separate fuse in the radio's own ground lead, as long as the supply fuse is of the proper value for the installation. I think the 'PowerPole' connector has the earmark of a classic 'Ham boondoggle'. I concede the possibility, in principle, of mismatings of the sort you mention. I've not ever heard of any occurring in practice. -- Dave Platt AE6EO Hosting the Jade Warrior home page: http://www.radagast.org/jade-warrior I do _not_ wish to receive unsolicited commercial email, and I will boycott any company which has the gall to send me such ads! |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
A Study of Amateur Radio Demographics | Policy | |||
FS: Coax Connectors, Switch, Relay | Swap | |||
Ranger II 8 prong plug | Boatanchors | |||
FS: Connectors, Antennas, Meters, Mounts, etc. | Antenna | |||
How-to seal coax connectors | CB |